Page 288 - Wieland - revos Industrial multipole connectors
P. 288

facts&DATA







        Definition of the IP degrees of protection




        For applications in industrial environments, degrees of   Practical notes:
        protections  and  standards  were  defined  that  specify   For  “normal”  industrial  systems  where  multipole
        the environmental impact regarding contact, protection   connectors  are  used  in  closed  factory  halls,  protec-
        against foreign bodies and humidity to which a system   tion according to IP54 is normally offered = protected
        can be exposed without being damaged. The degrees of   against dust + protected against splashing water. This
        protection are defined in the IP standard of DIN EN 60   protection is normally completely sufficient. For systems
        529: degrees of protection achieved through housings   in outdoor applications (vehicles, snow guns, etc.) we
        (IP code).                                            recommend protection according to IP65 = dustproof +
        The IP code consists of a two-digit number that indicates   protected against jets of water. A protection according
        the relevant protection degree. The first digit specifies   to IP67 or IP68 is required for only a few outdoor applica-
        the protection degree for the protection against contact   tions unless a continuous immersion of the components
        and foreign bodies while the second digit specifies the   cannot be avoided.
        protection against water and humidity.                The  following  tables  are  to  describe  the  protection
                                                              degrees in detail:





        Table 1: Protection against contact and foreign bodies


             1st     Protection against accidental contact    Protection against foreign bodies


              0      No protection                            No protection

                     Protection against contact with large parts of  Protection against foreign bodies
              1
                     the body, for example the back of the hand  with a diameter of 50 mm and larger.
                     Protection against contact with the finger   Protection against foreign bodies
              2
                     of 12.5 mm and larger.                   with a diameter of 12.5 mm and larger.
                     Protection against contact with tools and   Protection against foreign bodies
              3
                     wires larger than 2.5 mm                 with a diameter of 2.5 mm and larger.
                     Protection against contact with tools and   Protection against foreign bodies
              4
                     wires larger than 1 mm                   with a diameter of 1 mm and larger.
                                                              Protection against dust:
                                                              Penetration of dust is not fully prevented, but dust
                     Complete protection against
              5                                               must not penetrate to such an extent that the
                     accidental contact
                                                              equipment’s functionality or safety is restricted in any
                                                              way
                                                              Dustproof:
                     Complete protection against
              6                                               No penetration of dust possible with a negative
                     accidental contact
                                                              pressure of 20 mbar.

















       288                                                                                Subject to change without further notice
   283   284   285   286   287   288   289   290   291   292   293