Page 83 - Wieland - revos Industrial multipole connectors
P. 83
revos power
Dimensions
6-/36-pole + ground
60
Derating curve – 50
power contacts
according to IEC 60512 sec 3
revos power 40
6-/36-pole 30
Cross-section 4 mm 2 Current carrying capability [A] 20 Upper temperature limit
Cross-section 6 mm 2
Working current[A] 10
0
20 30 40 50 60 70 80 90 100 110 120 130
Ambient temperature [°C]
Ambient temperature [°C]
1-Wire gauge:6.0mm 2
Subject to change without further notice 83
2-Wire gauge:4.0mm 2
06-polig
10-polig
16-polig