Page 19 - Parker - AC10 Variable speed drive
P. 19
Variable Speed Drive - AC10
Order Code
Order Code
AC10
1 2 3 4 5 6 7
Order example 10 G - 1 1 - 0015 - B N
1 Product Family 1 Product Family
10 AC10 VFD - IP20 16 AC10 VFD - IP66
2 Industry 2 Industry
G General Purpose G General Purpose
3 Voltage 3 Voltage
1 230V Single Phase 1 230V Single Phase
3 230V Three Phase 3 230V Three Phase
4 480V Three Phase 4 480V Three Phase
4, 5 Frame Size, Rated Current 4, 5 Frame Size, Rated Current
230V Supply 230V Supply
1-0015 0.25 HP/0.2 kW 1-0025 0.5 HP/0.4 kW
1-0025 0.5 HP/0.4 kW 1-0045 1 HP/0.75 kW
1-0035 0.75 HP/0.55 kW 2-0070 2 HP/1.5 kW
1-0045 1 HP/0.75 kW 2-0100 3 HP/2.2 kW
2-0050 1.5 HP/1.1 kW 480V Supply
2-0070 2 HP/1.5 kW 1-0020 1 HP/0.75 kW
3-0100 3 HP/2.2 kW 1-0040 2 HP/1.5 kW
480V Supply 1-0065 3 HP/2.2 kW
1-0006 0.25 HP/0.2 kW 1-0090 5 HP/4.0 kW
1-0010 0.5 HP/0.4 kW 2-0120 7.5 HP/5.5 kW
1-0015 0.75 HP/0.55 kW 2-0170 10 HP/7.5 kW
2-0020 1 HP/0.75 kW 3-0230 15 HP/11 kW
2-0030 1.5 HP/1.1 kW 3-0320 20 HP/15 kW
2-0040 2 HP/1.5 kW 6 Braking Module
2-0065 3 HP/2.2 kW B Braking Module Installed
3-0090 5 HP/4.0 kW 7 EMC Filter
3-0120 7.5 HP/5.5 kW N No Filter Installed
4-0170 10 HP/7.5 kW F C3 EMC Filter Installed
4-0230 15 HP/11 kW
5-0320 20 HP/15 kW
5-0380 25 HP/18.5 kW
5-0440 30 HP/22 kW
6-0600 40 HP/30 kW
7-0750 50 HP/37 kW
7-0900 60 HP/45 kW
8-1100 75 HP/55 kW
8-1500 100 HP/75 kW
9-1800 125 HP/90 kW
9-2200 150 HP/110 kW
10-2650 200 HP/132 kW
11-3200 225 HP/160 kW
11-3600 250 HP/180 kW
6 Braking Module
B Braking Module Installed
7 EMC Filter
N No Filter Installed
F C3 EMC Filter Installed
19