            Notes:


            Copper and Stainless Tube                         Copper - Jacketed Tubing
            §Pressure data for temperatures above 200°F are   §Pressure data for temperatures above 200°F
            included for reference only.                      are included primarily for where single runs must
                                                              withstand higher ambient temperatures than the
            Plastic coated tubing should not be used at       Multitube bundle. The Multitube bundle should not be
            temperatures exceeding approximately 80°C due to   used at temperatures exceeding approximately 105°C
            the PVC (or PE) jacket employed.                  due to the PVC jacket employed. Consult the Division
                                                              if higher temperatures will be encountered.
            Copper - Armored Tubing
            §Pressure data for temperatures above 200°F       Stainless Steel - Jacketed Tubing
            are included primarily for where the tubing must   §Pressure data for temperatures above 200°F
            withstand higher ambient temperatures. The        are included primarily for where single runs must
            assembly should not be used at temperatures       withstand higher ambient temperatures than the
            exceeding approximately 80°C (176°F) due to the   Multitube bundle. The Multitube bundle should not be
            PVC tapes and jackets employed. Consult the       used at temperatures exceeding approximately 105°C
            Division if higher temperatures will be encountered.  due to the PVC jacket employed. Consult the Division
                                                              if higher temperatures will be encountered.


            Testing Specifications for Metal                     Testing Specifications for Plastic

            Tubing:                                              Tubing:

            All metal tubes used in the manufacture of Multitube   All plastic used in the manufacture of Multitube are
            are subject to stringent magnetic analysis using a   subject to rigorous Q.A. inspection and testing prior
            special eddy current tester. Each tube, after eddy   to shipment. Each tube is pressure tested at not
            current analysis, is pressure tested at not less than   less than 150 psi for 15 minutes without any sign of
            250 psi for 15 minutes without any sign of leakage.  leakage.

            When Multitube assemblies have completed the         When Multitube assemblies have completed the
            manufacturing process, each tube is again tested with   manufacturing process, each tube is again tested with
            dry N  at 250 psi for 5 minutes prior to shipment.   dry N  at 125 psi for 5 minutes prior to shipment.