Page 5 - Proportion-Air - QB3 Electro-Pneumatic Regulator
P. 5

PERFORMANCE CHARACTERISTICS


                                LINEARITY                                    RESPONSE TO STEP INPUT
                                 LINEARITY
                                                                   100
                   100
                                                                   90                                  Command
                    90                                             80                                   Pressure
                   Pressure [% of scale]  70                     % of Scale  60
                    80
                                                                   70
                    60
                                                                   50
                    50
                    40
                                                                   40
                    30
                    20
                                                                   20
                    10                                             30
                                                                   10
                     0
                                                                    0
                      0  1  2  3  4  5  6  7  8  9  10               -100  0   0.5  1   1.5  2   2.5  3 3  3.5  4
                                Command [Volts]
                                                                                                      Volume = 50 cu. in.
                                                                                     Time [seconds]
             This chart shows the linear characteristics of QB3    Times for QB3  to fill/exhaust a closed chamber.  Step
             products when given a ramp signal from 0-10 volts.    command signal is superimposed over pressure trace.
             Characteristics would be similar for 4-20 mA units.   Time is determined by difference between command
                                                                signal and pressure achieved.


                                                 FLOW CHARACTERISTICS

                                 QB3 Forward Flow
          120 (8.27)
                                               Fluid:  Air                  QB3 flow characteristics from no
          100 (6.82)                           Primary Pressure:  110 Psig (7.58)
                                               Bar)                         flow to full flow conditions.
         PSI (BAR)  80 (5.52)                                               assembly flow characteristics.
                                                                            Consult factory for sub-base
           60 (4.14)
           40 (2.16)

           20 (1.38)


               0
                         10 (4.72)  20 (9.44)  30 (14.16)  40 (18.88)  50 (23.60)
                                      SCFM (Liters/sec)
                                                                           QB3 Relief Flow
                                                  100 (6.82)

                                                  80 (5.52)
                                                PSI (BAR)  60 (4.14)



                                                  40 (2.16)

                                                  20 (1.38)
            QB3 flow characteristics from
            full flow to no flow conditions.
            Consult factory for sub-base
                                                                10 (4.72)   20 (9.44)  30 (14.16)  40 (18.88)  50 (23.60)
            assembly flow characteristics.
                                                                         SCFM (Liters/sec)

                                                                          LET’S TALK 317-335-2602   *   PROPORTION-AIR   *   BRQB011206E   5
   1   2   3   4   5   6   7   8