Page 100 - Parker - Solenoid Valves
P. 100

Catalog HY15-3502/US                              Spool Type, 4-Way Valve
                   Technical Information                             Series GS04 57D

                                                                                                                           CV
                   Dimensions Millimeters (Inches)
                                                                                          66.5
                                                                                          (2.62)                             Check  Valves
                                                            Manual Override                           22.0
                                 36.0
                                (1.42)                      (Latch and Pull or Push)                  (0.86)               SH
                                                              25.4 Dia                                  36.0
                                                              (1.00)                                   (1.43)                Shuttle  Valves
                                                              Finger Tight
                                                              Torque
                                      50.0                                                                                 LM
                                     (1.97)      MADEINU.S.A.  PAT.XXXXXXX  CAX  XXX  H  XXVDC    XXW  Pull
                                                                                                                             Load/Motor  Controls
                                                             b


                                            Push                                                                           FC
                                     50.0    a
                                     (1.97)
                                          19.0
                                          (0.75)                     See Super Coil                                          Flow  Controls
                                                                     5/8" I.D.
                                                                     Information For
                                191.2                                Terminal Connectors                                   PC
                                (7.53)
                                                              1" Hex.
                                                              34 Nm (25 lb. ft.)
                                                              Torque                                                         Pressure  Controls
                                                 (4)          7/8-14 UNF
                                          62.7                Thread                                                       LE
                                          (2.47)  (3)
                                                 (2)                                                                          Elements
                                                                                                                             Logic
                                              15.8   (1)
                                             (0.62)                                                              THIRD-ANGLE  DC
                                                                                                                 PROJECTION
                                                                                                                             Directional  Controls
                   Ordering Information

                     GS04         57                              D                                                        MV

                      10 Size     Style  Override  Screen  Seals  Design  Coil   Coil    Coil    Body     Port               Manual
                   Solenoid Valve        Option                  Level   Type   Voltage  Termination  Material  Size          Valves
                                                                                                                           SV
                    Code Style                 Code Seals / Kit No.  Code Coil Termination   Code Body Material
                    57  High Flow and Pressure  N  Nitrile / Buna-N (Std.)  Omit Without Coil  Omit Steel
                        (‘SP’ Coil)                (SK30506N-1)       C  Conduit With Leads   A  Aluminum                    Solenoid  Valves
                                                V  Fluorocarbon /     D  DIN Plug Face
                    Code Override Options          (SK30506V-1)       A  Amp Jr. Timer*      Code Port Size  Body Part No.  PV
                     0  None                                          S  Dual Spade*         Omit Cartridge Only
                     5  Standard - Latch Operated,  Code Design Level  L  Dual Lead Wire*     8T  SAE-8  (B10-4-*8T)         Proportional
                        Pull and Push (*40 nt/9 lbs.)  D  Includes Industry                                                   Valves
                   *Force to push at 210 Bar (3000 PSI).  Common Cavity  LS  Sealed Lead Wire*  8B  1/2″ BSPG (B10-4-*8B)
                   Less to Pull.                                      H  Molded Deutsch*    * Add “A” for aluminum, omit for steel.  CE
                                                                    See Super Coil 5/8″″ ″″ ″ I.D.
                                               Code Coil Type
                    Code Screen                                     *DC Only
                                               Omit Without Coil                                                              Electronics
                     0  None                                                                                                 Coils &
                        (Contact factory for    SP  Super Coil - 28 Watts
                        OEM requirements)
                                                                                                                           BC
                                               Code Coil Voltage
                                               Omit Without Coil
                                               D012 12 VDC                                                                   Bodies &  Cavities
                                               D024 24 VDC
                                               A120 120 VAC, 60/50 Hz                                                      TD
                                               A240 240 VAC, 60/50 Hz*
                                                                                                                             Technical  Data
                                               *22 Watts

                                                                   SV98                        Parker Hannifin Corporation
                                                                                               Hydraulic Cartridge Systems