Page 31 - Parker - Solenoid Valves
P. 31
Catalog HY15-3502/US Poppet Type, 2-Way Valve
Technical Information Series DSL201
CV
General Description
2-Way Poppet Valves. For additional
information see Technical Tips on
Valves
Check
SH pages SV1-SV6.
Features
Valves
Shuttle
LM • Replaceable, one piece encapsulated coils with minimal
amperage draw
• Various coil terminations and voltages
• Various manual override options Out (1)
DSL201C
Load/Motor
Controls
FC • All external parts zinc plated In
• New 250 Bar (3600 PSI) rating (2)
In (2)
Out (1)
DSL201N In
NOTE: Out (1) (2) DSL201N
Controls
Flow
PC This valve will be available January 1, 2011.
Out (1)
Specifications In (2) DSL201C
Controls
Pressure
LE Rated Flow 260 LPM (70 GPM) Performance Curve
(At 70 PSI ∆∆ ∆∆ ∆P)
Pressure Drop vs. Flow (Through cartridge only)
Maximum Inlet 250 Bar (3600 PSI) PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)
Logic
Pressure 100 6.9
Elements
DC
Leakage at 5 drops/min. (.33 cc/min.)
80 5.5
150 SSU (32 cSt)
P)
Controls
Directional
Minimum 85% of rated voltage at 60 4.1
MV Operating Voltage 20°C (72°F). Out-In
Response Time Energized De-Energized Pressure Drop ( 40 2.8
C, CR 350 ms 160 ms In-Out
Valves
N, NR 300 ms 45 ms
Manual
SV 20 1.4
Cartridge Material All parts steel. All operating
parts hardened steel. 0
LPM 76 151 227 303
0
GPM 20 40 60 80
Valves
Solenoid
Operating Temp. -40°C to +93.3°C (Nitrile) Flow (Q)
PV Range/Seals (-40°F to +200°F)
-31.7°C to +121.1°C (Fluorocarbon)
(-25°F to +250°F)
Valves
Proportional
Fluid Mineral-based or synthetic with
CE Compatibility/ lubricating properties at viscosities
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Filtration ISO Code 16/13,
SAE Class 4 or better
Coils &
Electronics
BC
Approx. Weight .34 kg (.75 lbs.)
Cavity C20-2
(See BC Section for more details)
Bodies &
Cavities
TD
Form Tool Rougher None
Finisher NFT20-2F
Technical
Data
SV29 Parker Hannifin Corporation
Hydraulic Cartridge Systems