Page 9 - Parker - Solenoid Valves
P. 9
Catalog HY15-3502/US Spool Type, 2-Way Valve
Technical Information Series GS02 22
CV
General Description
2-Way, 2 Position, Normally Closed Spool Valve.
For additional information see Technical Tips on
Check
Valves
SH pages SV1-SV6.
Features
Valves
Shuttle
LM • High flow capacity
• One piece cartridge housing ensures internal
concentricity
• Coil: Waterproof, hermetically sealed, requires no
Controls
Load/Motor
O’Rings; Symmetrical coil can be reversed without (1)
FC
affecting performance.
(2)
Flow
Controls
(2)
PC
(1)
Pressure
Controls
LE
Specifications Performance Curves
Pressure Drop vs. Flow (Through cartridge only)
Elements
Logic
DC Rated Flow 13 LPM (3.5 GPM) PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)
(At 70 PSI ∆∆ ∆∆ ∆P)
200 14.0
Maximum Inlet 350 Bar (5000 PSI) 150 10.5
Pressure
Directional
Controls
MV Pressure Drop 100 7.0
Leakage at 82 cc/min @ 210 Bar (3000 PSI)
150 SSU (32 cSt) 50 3.5
Minimum 85% of rated voltage at
Manual
Valves
0
SV Operating Voltage 20°C (72°F). LPM 3.8 7.6 11.4 15.2 18.9
0
GPM 1 2 3 4 5
Cartridge Material All parts steel. All operating Flow (Q)
parts hardened steel.
Opreating Limits (Measured at 75% of Nominal Current)
Solenoid
Valves
PV Operating Temp. -40°C to +93.3°C (Nitrile) PSI Bar Hydraulic Oil 150 SSU @ 100°F (32 cSt)
Range/Seals (-40°F to +200°F)
-31.7°C to +121.1°C (Fluorocarbon) 2 to 1
(-25°F to +250°F) 5000 350
Valves
Proportional
CE Fluid Mineral-based or synthetic with 4000 280
Pressure 3000 210
Compatibility/ lubricating properties at viscosities 1 to 2
Viscosity of 45 to 2000 SSU (6 to 420 cSt)
Filtration ISO Code 16/13,
Electronics
2000 140
Coils &
SAE Class 4 or better
BC Reduce Flow By 10%
For Manual Override
1000 70
Approx. Weight .14 kg (.31 lbs.)
0
Cavity C09-2 LPM 3.8 7.6 11.4 15.2 18.9
Bodies &
Cavities
TD (See BC Section for more details) GPM 0 1 2 3 4 5
Flow (Q)
Data
Technical
SV7 Parker Hannifin Corporation
Hydraulic Cartridge Systems