Page 2 - Parker - BEVPOR MH bottled water filter cartridges
P. 2

BEVPOR MH

                                                                                         Bottled Water










          Specifications

          Materials of Construction          Effective Filtration Area (EFA)     Integrity Test Data
          ❙ Filtration Membrane:   Polyethersulphone  10¨ (250 mm)   Up to 0.8 m  (8.61 ft )  All filters are flushed with pharmaceutical
                                                                    2
                                                                         2
          ❙ Prefilter Layer:   Polyester                                         grade purified water prior to despatch. They
          ❙ Upstream Support:   Polyester    Cleaning and Sterilization          are integrity tested to the following limits:
          ❙ Downstream Support:   Polyester  BEVPOR MH cartridges can be repeatedly
          ❙ Inner Support Core:   Polypropylene  steam sterilized in-situ or autoclaved at up
          ❙ Outer Protection Cage:   Polypropylene  to 130 °C (266 °F). They can be sanitized with      Diffusional Flow             Micron Rating
          ❙ End Caps:       Nylon            hot water at up to 90 °C (194 °F) and are    Test Parameters      0.20   0.45
          ❙ End Cap Insert:   316L Stainless Steel  compatible with a wide range of chemicals.
          ❙ O-rings:        Silicone / EPDM  Please refer to our Clean-in-Place support     Test Pressure (barg)      2.4   1.7
                                             guide or contact your local Parker      Test Pressure (psig)      35.0   25.0
                                             representative for more information.    Max Diffusional
          Food Contact Compliance                                                  Flow per 10¨ (ml /min)      21.0   21.0
          Materials conform to the relevant    Retention Characteristics
          requirements of FDA 21CFR Part     0.2µm BEVPOR MH filters have been
          177, current EC1935 / 2004 and current USP   validated to provide sterile effluent after    Manufacturing Traceability
          Plastics Class VI - 121 °C.        bacterial challenge testing following ASTM   Each filter cartridge displays the product
                                             F838-05 methodology on 10” cartridges with   name, product code and lot number.
                                             more than 10 cfu per cm  using      Additionally, each module displays a unique
                                                      7
                                                              2
          Recommended Operating Conditions   Brevundimonas diminuta.             serial number providing full manufacturing
          Up to 70 °C (158 °F) continuous operating                              traceability.
          temperature and higher short-term  In addition, challenges with the following EU
          temperatures during CIP to the following  regulated organisms have been performed.
          limits:
                                               Organism               LRV when challenged with a
            Temperature                  Max Forward dP                                    minimum of 10  cfu per cm 2
                                                                   7
            °C     °F         (bar)   (psi)                      0.20   0.45
            20     68         5.0  72.5
            40     104        4.0   58.0       Serratia marcescens   FR  FR
            60     140        3.0   43.5       Escherichia coli      FR  FR
            80     176        2.0   29.0       Enterococcus faecalis   FR  FR
            90     194        1.0   14.5       Clostridium perfringens   FR  FR
          >100 (steam)  >212 (steam)   0.3   4.0    Pseudomonas aeruginosa   FR   FR
                                               Brevundimonas diminuta   FR  5
                                             *FR - Fully retentive during challenge
                                             When expressed as titre reduction “FR” equates to
                                             >10 7  per 10¨module.                                                    Europe: ✆ +44 (0)191 4105121    dhprocess@parker .com   |   North America: ✆ toll free: +1 877 784 2234    dhpsales.na@parker .com  |  www.parker .com/dhbottledwater



          Ordering information


           BMH -                            -            A


                   Code   |   Length (Nominal)  Code   |   Micron  Code   |   End Cap (10 inch)  Code   |   O-rings
                   1   10¨   (250 mm)  02   0.20  µm  C   Fin / 226 Bayonet  S  Silicone
                   2   20¨   (500 mm)  04   0.45  µm  D   Fin / 222  E  EPDM
                   3   30¨   (750 mm)          E   Flat Top / 222
                   4   40¨   (1000 mm)         G   Recess / 222
                                               R   BF / 222 Bayonet






                                                                                                       VSH & HSL
                                                                                                       HOUSING RANGE
                                                                                                         AVAILABLE



          Parker domnick hunter has a continuous policy of product development and although the Company reserves the right to change specifications, it attempts to keep customers informed of   DS_BW_08_01/14 Rev. 1B
          any alterations. This publication is for general information only and customers are requested to contact our Process Filtration Sales Department for detailed information and advice on a
          products suitability for specific applications. All products are sold subject to the company’s standard conditions of sale.
   1   2