Operational parameters. Life time recommendations


            Life time recommendations
            Linde high pressure units are designed for excellent reliability and long service life. The actual service life of a hydraulic unit is
            determined by numerous factors. It can be extended significantly through proper maintenance of the hydraulic system and by using
            high-quality hydraulic fluid.



            Beneficial conditions for long service life
            >> Speed          lower continuous maximum speed
            >> Operating pressure  less than 300 bar Δp on average
            >> Max. pressure   only at reduced displacement
            >> Viscosity      15 ... 30 cSt
            >> Power          continuous power or lower
            >> Purity of fluid   18/16/13 in accordance with ISO 4406 or better

            Adverse factors affecting service life
            >> Speed          between continuous maximum speed and
                              intermittent maximum speed
            >> Operating pressure  more than 300 bar Δp on average
            >> Viscosity      less than 10 cSt
            >> Power          continuous operation close to maximum power
            >> Purity of fluid   lower than 18/16/13 in accordance with ISO 4406