Page 43 - Viledon - Air and Liquid Filtration
P. 43
Cassette filters
NanoPleat | Fine dust
AIR FILTERS CLASS M5 – F9
Specifications
Filter medium HSN media technology
Recommended final pressure drop 450 Pa
Thermal stability up to 70 °C
Moisture resistance 100 % rel. hum.
Frame Plastic
Application
®
Viledon NanoPleat filters have been developed specifically for intake, exhaust The pleated HSN filter media, cast in a tough plastic frame in a leakproof
and recirculated air filtration in HVAC systems posing stringent requirements for configuration, are exceptionally sturdy and water-repellent. Even when
clean air quality and cost-efficiency. They ensure clean, efficiently conditioned air exposed to high levels of dampness and moisture, the filter medium will not be
saturated; in fact the water droplets will simply roll off the material’s surface.
in office buildings, production halls, airports, libraries, museums, laboratories, The pressure drop remains almost unchanged even under these circumstances,
hospitals, old people’s homes and care facilities, etc., thus providing maximized operational reliability.
in sensitive applications for the food and beverage industries, pharmaceuticals, ®
chemicals, optics, electronics, and medical technology, etc. Viledon NanoPleat filters are highly resistant to chemicals, microbiologically
inert and meet all hygiene requirements for HVAC systems to EN 13779 and
Special features and benefits the German VDI Guideline 6022. Their microbial safety has been confirmed
by the Institute for Air Hygiene in Berlin.
Consistently high filtration efficiency under all operating conditions thanks to The sturdy construction ensures optimum performance even under turbulent
the unique HSN media. flow conditions or during load changes. This means that the risk of particle or
The low pressure drop and the high dust holding capacity provide ultra-
fiber shedding is practically eliminated.
efficient, energy-saving operating characteristics, with a slow increase in the The filter elements are free of metals and halogens, corrosion-proof and also
pressure drop and resultant additional lifetime reserves. This produces a fully incinerable and thus disposal-friendly. The frame and filter media are
significant reduction in operating costs.
Simplified handling at installation, since the HSN medium will not be self-extinguishing to DIN 53438 (Fire class F 1).
irreversibly damaged even if it comes into contact with slight pressure.
Article Article Dimensions Filter Nominal Initial Initial Minimum Average Weight Energy efficiency
number (W × L × D) class volume pressure efficiency efficiency efficiency [kg] classification according to
[mm] flow drop [%] [%] [%] EUROVENT 4/21*
3
[m / h] [Pa] Nominal Energy Annual
volume class Energy
flow consump-
[m³ / h] tion**
MV 75 HSN 1/1 V08x24-Z00N-A33 53424217 592 × 592 × 292 M 6 3,400 85 43 ≥ 70 5.8 3.400 E 1,640
MV 75 HSN 5/6 V08x24-Z00N-A33 53429115 490 × 592 × 292 M 6 2,700 85 40 ≥ 70 4.8 2.700 E
MV 75 HSN 4/6 V08x24-Z00N-B33 53475720 405 × 592 × 292 M 6 2,100 85 40 ≥ 70 4.6 2.100 E
MV 75 HSN 1/2 V08x24-Z00N-A33 53429114 287 × 592 × 292 M 6 1,500 85 40 ≥ 70 3.3 1.500 E
MV 85 HSN 1/1 V08x24-Z00N-B33 53424218 592 × 592 × 292 F 7 3,400 100 60 57 ≥ 85 5.8 3.400 C 1,500
MV 85 HSN 5/6 V08x24-Z00N-B33 53429117 490 × 592 × 292 F 7 2,700 100 60 57 ≥ 85 4.8 2.700 C
MV 85 HSN 4/6 V08x24-Z00N-B33 53441273 405 × 592 × 292 F 7 2,100 100 60 57 ≥ 85 4.6 2.100 C
MV 85 HSN 1/2 V08x24-Z00N-B33 53429116 287 × 592 × 292 F 7 1,500 100 60 57 ≥ 85 3.3 1.500 C
MV 95 HSN 1/1 V08x24-Z00N-C33 53424229 592 × 592 × 292 F 8 3,400 110 70 67 ≥ 90 5.8 3.400 C 1,700
MV 95 HSN 5/6 V08x24-Z00N-C33 53429124 490 × 592 × 292 F 8 2,700 110 70 67 ≥ 90 4.8 2.700 C
MV 95 HSN 4/6 V08x24-Z00N-C33 53441279 405 × 592 × 292 F 8 2,100 110 70 67 ≥ 90 4.6 2.100 C C
1,500
3.3
≥ 90
67
110
70
F 8
1.500
53429118
Subject to technical changes. MV 98 HSN 1/1 V08x24-Z00N-D33 53424230 592 × 592 × 292 F 9 3,400 120 75 72 > 95 5.8 3.400 B B B B 1,690 43
MV 95 HSN 1/2 V08x24-Z00N-C33
287 × 592 × 292
MV 98 HSN 1/2 V08x24-Z00N-D33
75
287 × 952 × 292
2.700
72
120
F 9
2,700
3.3
53429135
> 95
F 9
> 95
2.100
72
120
53490992
2,100
4.6
MV 98 HSN 4/6 V08x24-Z00N-D33
75
405 × 592 × 292
4.8
1.500
490 × 592 × 292
F 9
MV 98 HSN 5/6 V08x24-Z00N-D33
53429134
1,500
72
> 95
120
75
* rated at 3,400 m 3 /h (further information at www.eurovent-certification.com)
** The specified annual energy consumption is the result of laboratory tests using synthetic test dust and refers only to the proportion of total energy
consumption attributable to flow resistance through the filter. The annual energy consumption of an HVAC system in operation can therefore
differ significantly under actual operational conditions.