Cassette filters
MVPGT | EPA
Specifications
Recommended final pressure drop 600 Pa
Bursting pressure 3,700 Pa
Thermal stability 70 °C
Moisture resistance 100 % rel. hum.
Frame Halogen-free plastic
Seal Flat seal, glued
Protection grids Halogen-free plastic, on the clean air side
Application Advantages
Viledon MVPGT cassette filters are used in intake air filtration for gas turbines Low pressure drop values.
®
and turbocompressors on the mainland. They are particularly well suited for Filtering area in accordance with industrial standard.
locations with low dust concentrations, with volume flows of ≤ 5,000 m / h per High dust holding capacity.
3
filter unit and for systems with ≤ 6,000 operating hours / year. Casting the dimensionally stable pleat package into the plastic frame assures a
high degree of security against dust breakthrough and a high pressure surge
withstand capability over the entire operational lifetime.
Subject to technical changes. Article Article Dimensions E 10 Nominal Initial pressure Arrestance Filter area 49
Filter class
drop
efficiency MPPS
volume flow
[m ]
number
(W × L × D)
2
[%]
[Pa]
[m / h]
[mm]
3
53464952
18
MVPGTE10-P-0593x0593x292/V08x25-W19N
240
4,250
≥ 85
592 × 592 × 292
www.freudenberg-filter.com