Page 172 - Ballyclare Workwear Catalogue 2021
P. 172

EN 13034                          EN ISO 20471                        RIS-3279-TOM                                      EN 343









        EN 13034                            EN ISO 20471                         RIS-3279-TOM
        Protective clothing for limited     High visibility clothing.            Rail industry standard for high               EN 343
        protection against liquid chemicals.                                     visibility clothing.                          Protective clothing for protection
                                            EN ISO 20471 specifies the require-                                                 against rain.
        EN 13034 specifies the               ments for high visibility clothing to   RIS-3279-TOM specifies the mini-
        requirements for limited protection   the visual presence of the passive   mum requirements for high visibi-           EN 343 specifies the requirements
        against small splashes or light mist   road user in both day light and low   lity clothing that is to be provided      for the clothing with protection
        of chemical fluids. The standard has   light situations. The standard is split   for wearing by people when on the      against precipitation (rain, snow,
        the following tests and             into 3 classes.                      lineside or on or near the line of an         but also fog and humidity off the
        requirements:                                                            operational railway. The standard is          ground). The standard imposes re-
                                            •       Class 1: traffic speed is     always applied in conjunction with            quirements on material and seams.
        Wear resistance according to                ≤ 30 km/hour                 EN 20471.
        Martindale abrasion.                •       Class 2: traffic speed is                                                   Water penetration
        - Minimum class 1: 10 revs                  ≤ 60 km/h and > 30 km/h                                                    •      X : 4 classes where 4 is the
                                            •       Class 3: traffic speed is                                                          highest class and indicates
        Tear strength                               > 60 km/hour                                                                      the highest level of
        (trapezium test sample)                                                                                                       protection.
        - Minimum class 1: 10 N
                                            The classification is made on the                                                   Water vapour permeability
        Tensile strength                    basis of the proportion of fluo-                                                    •      Y: 4 classes where 4 is the
        - Minimum class 1: 30 N             rescent material (HV color) and                                                           highest class and indicates
                                            proportion retroreflecting material.                                                       the highest level of
        Puncture resistance                 Requirements are set for the colour                                                       protection.
        - Minimum class 1: 5 N              quality, brightness and reflection
                                            in new condition, but also after                                                   In addition to requirements for
        Liquid repulsion                    washing and exposure to xenon                                                      water penetration and water
        1.     H2SO4 30% (sulphuric acid)   light.                                                                             vapour permeability set within the
        2.     NaOH 10% (caustic soda)                                                                                         standard there are also require-
        3.     o-Xylene                     In addition to material properties,                                                ments for mechanical strength and
        4.     Butan-1-ol                   the standard specifies the fluo-                                                     provision of
               At least 1 liquid class 3:   rescent positioning requirements                                                   information (user manual).
               > 95%                        and retroreflective material as well
                                            as to the mechanical properties
        Resistance to fluid penetration      and  provision of information (user
        1.     H2SO4 30% (sulphuric acid)   manual).
        2.     NaOH 10% (caustic soda)
        3.     o-Xylene
        4.     Butan-1-ol
               At least 1 liquid class 2:
               < 5%

        Seam strength
        Minimum class 1: > 30 N

        Clothing test
        -      Type PB 6 clothing: offers
               partial protection
        -      Type 6 clothing: protection
               to the whole body (=with
               the exception of head,
               hands and feet).
        -      spray/mist test: no
               penetra tion by the
               clothing.

        In addition to material and
        garment properties the standard
        has information requirements
        (user manual).

        172                                                                                                                                                                                                BALLYCLARELIMITED.COM | 173
   167   168   169   170   171   172   173   174   175   176   177