Page 81 - Critical Control flipbook_Neat
P. 81

Structural Collapse











           1    What is the name of           2    What are its specific objectives related to the Priority Unwanted
                the critical control for
                                                   Event (PUE)?
                Structural Collapse?
          Quality Control and Assurance of new or   Design of new (or modified) structures follow a Quality Assurance and Quality Control
          modified structures                process ensuring redundant review and verification by a competent resource


           3    What are the critical         4    What are the activities       5    What can be sampled from
                control performance
                                                   within the management
                                                                                      the set of activities for
                requirements to meet the           systems that support               verification, providing a
                objectives?                        having the critical control        clear image of the critical
                                                   able to do what is required?       control status?
          Peer review of design verifies compliance   Design prepared by accredited and   Peer review record available for new/
          to construction code and industry good   certified engineers          modified structures
          practice                           Approved competent peer reviewers list
                                             Peer review process including formal
                                             follow-up of  actions from reviews

          Supervision and QC/QA process during   Formal approval of deviations from   Record of approval on blueprint
          erection controls the quality of materials,   blueprint by competent engineer  deviations
          workmanship and compliance to original
          design

          Equipment design facilitates access to   Project design review process includes   Blueprints and drawings aligned with
          sliding connections and joints; prevents   details of provisions to access sliding   project design review
          leakage and accumulation of material  connections and means to keep them
                                             clean

           6    What is the target performance for critical     7    What is the critical control performance
                control?
                                                                     trigger for shutdown, critical control review or
                                                                     investigation?
          Structural design is implemented according to building code and   Designs not peer reviewed
          Holcim design criteria, ensuring no deviations compromising the   QA/QC process not followed
          quality of materials, workmanship and design         Final design fails to address easy access and accumulation of
                                                               material at sliding connections and joints



























          Creation date: 01/2021 • The latest and only controlled version of this document is available on the HSE intranet.
          © 2021 Holcim - For internal use only