Page 52 - Zero is Possible - Volume 2 Grey
P. 52

Ready-mix Site Safety Check




       Traffic routes                       Liquid fuel installation             Operating room
        1  One-way systems and no light      1  Access restricted and physical    1  A main switch
           vehicles in heavy equipment areas    barriers to prevent impact           to stop the entire site
        2  Clear signage and markings to ensure   2  Fuel tank with sensor        2  LOTOTO station with access to
           traffic rules are easily understood  level and vents                      isolation devices
        3  Pedestrians’ pathways around the site   3    Fire detection and suppression,   3  Energy, water withdrawal, and
           and crossings with stop-and-go gates  earthing and lightning              discharge measuring devices
       Raw material storage area             4  Secondary containment and spill   Other working areas
                                                emergency kit
        1  Access control                                                         1  Lab with a hoist, adjustable-height
           with physical barriers           Conveyor belts                           benches, and ventilation
        2  Flat ground and no power lines    1  Guarded, and equipped with        2  Bulk cement unloading station with
           over the unloading area              emergency stops and pull cords       safety chain to hold the hose
        3  Water sprays                      2  Platforms with guardrails, handrails,   3  Concrete sludge recycling fenced,
           to control dust                      and toe boards                       and with life buoy adult lifesaving
        4    Loaders with warning systems and   3  Visual cutoff switches to easily lock   4    Ready-mix trucks washing platforms
           occupant protection                  out the equipment                    with handrails, and toe boards
                                                                                       Parking lot, loading, and offloading
       Maintenance facilities               Cement silos                          5  areas with permanent wheel chocks
        1  Hot work designated areas with    1  Silo pressure control system: level   6    General facilities
           cylinders stored separately          sensor, pressure sensor, and relief valve  cleaned and tied
        2  Separate chemical storage with    2  Baghouse in the top of the silo    7    Roads sloped towards a collection
           secondary containment                for dedusting                        point linked to a water treatment plan
           Tire storage and cages               Guardrails, handrails, and toe boards
        3                                    3
           to calibrate it                      at the top of the silos
        4  A drainage system                 4  Stairs to access the top
           with an oil trap                     of the silo



    42