Page 54 - Zero is Possible - Volume 2 Grey
P. 54

Quarry Roads Safety Check




       Quarry roads must meet the following requirements:


                                                                                       Rock trap
             Hold point
                                                  Access restrictions
        1   Set up for light mobile          5   Block-off physically restricting   9   Installed along non-active faces
           equipment to only pass once          access to inactive areas.            and designed at the base of
           permission from the heavy                                                 a face to stop or retain falling
                                                  Berms
           mobile equipment is obtained.     6   The height of the continuous        rocks.
             Segregation
                                                                                       Slope
        2   Heavy and light vehicles            safety berm should be half       10  The inclination of a haul road
                                                the diameter of the largest tire
           segregated by a physical barrier     traveling on the road.               for off-road dump trucks should
           (aggregates) wherever possible.                                           not exceed 8%.
                                                  Drainage
                                             7   Drainage ditches along the side       Maintenance
             Signage
        3   Use signage throughout              of the road.                     11  Regular maintenance to keep
           the quarry to alert potential        The ditch depth value is 0.33m       roads in good condition, without
           hazards, provide directions, and     lower than the road surface.         rocks and debris.
           communicate rules.
                                                  Road width
                                             8   The width of the road should
             Runaway provisions
        4   Physical mitigation for the case    be 2.5x the width of the largest
           of runaway mobile equipment          vehicle for one-way road and
           where the grade is greater than      3.5x for two-way road.
           10%.








    44