Building Services
Console TYPE 27/18
• Galvanised, assembly-ready cantilever bracket
• Robot-controlled precision welding – highest safety and stability
• Good adaptation to structural requirements thanks to graduated
lengths
• The mounting holes in the base plate are punched slots at 90° to
each other, to improve ease of installation
• Also suitable for fixing to ceilings
Areas of application:
• Projecting support structures for pipe sections, fittings, cable racks,
pumps, ventilation ducts, ventilation units and air-conditioning units
Article No. Article Description QTY
8545 200 CONSOLE GAL.TYPE 27/18 200MM e 25
8545 300 CONSOLE GAL.TYPE 27/18 300MM e 25
Load values in Newton (N) for console TYPE 27/18
F F F A F A F A F A F
A A A A A A A
Length projection mm Total length mm F = single load F = single load F = single load F = single load Distributed load
L
L
L
L
L
A = 1/4 × L
A = L
A = 1/2 × L
A = 1/3 × L
200 204 530 265 265 177 2.650
300 304 352 140 176 117 1.174
Console TYPE 28/30
• Galvanised, assembly-ready cantilever bracket
• Robot-controlled precision welding – highest safety and stability
• Good adaptation to structural requirements thanks to graduated
lengths
• The mounting holes in the base plate are punched slots at 90° to
each other, to improve ease of installation
• Also suitable for fixing to ceilings
Areas of application:
• Projecting support structures for pipe sections, fittings, cable racks,
pumps, ventilation ducts, ventilation units and air-conditioning units
Article No. Article Description QTY
8546 250 CONSOLE GAL.TYPE 28/30 250MM e 25
8546 350 CONSOLE GAL.TYPE 28/30 350MM e 25
8546 400 CONSOLE GAL.TYPE 28/30 400MM e 25
8546 550 CONSOLE GAL.TYPE 28/30 550MM e 10
Load values in Newton (N) for console TYPE 28/30
F F F A F A F A F A F
A A A A A A A
L
Length projection mm Total length mm F = single load F = single load F = single load F = single load Distributed load
L
L
L
L
A = 1/3 × L
A = 1/2 × L
A = 1/4 × L
A = L
250 254 1.354 677 677 450 1.354
350 354 965 482 482 322 964
400 404 843 421 421 281 842
550 554 610 305 305 203 610
When calculating the load-bearing capacity values, the permissible steel stress of 160 N/mm² and the maximum deflection of L/150 are not exceeded.
The loads indicated only apply to the console.
The other design parts must be tested for their permissible maximum load too.