Page 3 - EMU MLY.pdf
P. 3

6. Replacement of VRLA batteries with LMLA batteries:

             Replacing  the  existing  LMLA  Batteries  after  completing  Coadal  life  (4  years)  with  VRLA
            Batteries  due  to  LMLA  needs  more  maintenance(checking  of  electrolyte,  adding  of
            electrolyte,water regularly)


















            7. Modification of Gear case and suspension bearing Oil Sump Caps:

            Wing nut type filling Caps have been provided for  Gear Case,  it is found  wing nuts are
            being worked out on run and causing spillage.

            Spring loaded  filling Caps have been provided for Suspension Bearing oil sumps, it is found
            the caps are being worked out on run and causing spillage.

            To avoid this Threaded type Caps have been provided in EMU & MEMU Conventional MCs
            for Gear Case & Suspension Bearing oil sump.



























                                                                                                   Page 3 of 5