Page 2 - Glass Fitting Instructions
P. 2

STRUCTURAL LANDING GLASS:

       1. We recommend that you start with the first   6. Depending on what fixing system has been
         landing pane at the top of the stairs as this will   provided:
         set the height for all the other panes.  i) Drill out all the holes in the trimmer at 20mm
       2. Fit a batten to the underside of the ceiling   diameter, to a depth of at least 42mm, then
         joist to rest the glass panes on, or under the   wind in the 30mm long threaded inserts,
         ceiling if already plastered.  If the balustrade   using a 12mm hexagon key or similar, until
         is above a wall, then measure the height of   flush with the face of the trimmer.
         the panel and fit a batten to the wall ensuring   ii) Drill out the trimmer will a 9mm drill bit and
         that the glass pane will be 920mm above the   insert the 100mm wood-metal screws to the
         chipboard.                           correct depth (protruding 20mm from the
       3. Offer up the first pane, normally the first   trimmer).
         landing pane at the top of the stairs, but check   7. Offer the pane back up and secure in place
         plan detail for confirmation, keeping it 20mm   with two or three flat face clamps (using
         back from the end (whether this is a newel,   the 60mm bolts in the inserts), leaving the
         landing wall or trimmer etc.).       majority of the clamps loose for now for
       4. Depending on where the batten is from   adjustment.  Remember to fit the 2mm plastic
         point 2, position a packer under each bottom   washer behind the glass.
         corner of the glass pane and adjust to suit so   8. Continue steps 2 to 6 working around the
         the vertical edge is aligned with the top newel   landing, ensuring the tops of the panes line up
         or landing wall as relevant (the top of the pane   and the vertical faces are about 20mm apart.
         is to be 920mm above the chipboard).  9. Once all the panes are in position and
       5. Mark the centre of the fixing holes and   adjusted to align up, fit the rest of the bolts
         remove the pane.                     and flat face nuts to secure the glass,
                                              fastening the bolts up evenly.


                                                          12mm toughened
                                                          glass
                                                          Timber trim
                      False                           Flooring finish
                      string                          Chipboard

                          Glass fixing -
                          flat face nut,
                          bolt and
                          threaded insert
                                                           Landing
                                                           trimmer
                      Plastic
                      washers
                                                              False string
                                                              fixings with
                          Routed sections                     grain plugs
                          over glass fixings
                          in false string
                      Glass fixings -                  Plasterboard
                      wood to metal
                      dowel screws
                      and flat face nut   Capping 50 x 10mm
   1   2   3   4   5   6