Page 3 - Glass Fitting Instructions
P. 3
STRUCTURAL FLIGHT GLASS:
1. Fit a batten to the underside of the stair string 6. Offer the pane back up and secure in place
to rest the glass panes on. with two or three flat face clamps (using
2. Offer up the top pane first, keeping it 20mm the 40mm bolts in the inserts), leaving
back from the top (whether this is a newel, the majority of the clamps loose for now.
landing pane or trimmer etc.). Remember to fit the 2mm plastic washer
3. Position a packer under each bottom corner of behind the glass.
the glass pane and adjust to suit so the vertical 7. Continue steps 2 to 6 working down the
edge is aligned with the top newel or landing staircase to the bottom, ensuring the tops of
pane as relevant (the top of the pane is to be the panes line up and the vertical faces are
920mm above the pitch line of the nosings, or about 20mm apart.
to align with the adjacent landing pane). 8. Once all the panes are in position and
4. Mark the centre of the fixing holes and adjusted to align up, fit the rest of the bolts
remove the pane. and flat face nuts to secure the glass,
5. Drill out all the holes in the strings at 20mm fastening the bolts up evenly.
diameter, to a depth of 22mm (using a forstner
bit or similar) then wind in the 20mm long
threaded inserts using a 12mm hexagon key.
Round handrail
siliconed on to
the top of the
glass
12mm toughened
glass
False string
20 x 247mm
Tread
Glass fixing -
flat face nut, False string
bolt and fixings with
threaded insert grain plug
Plastic
washers Timber String
32 x 235mm
Routed sections
over glass fixings
in false string
Plasterboard
Capping 10 x 50mm