Page 5 - Industrial Technology EXTRA 16th August 2021
P. 5

The solution allows the team to continue to
       train, while the club can maintain the condition
       of its training pitch to the required standard at
       no extra cost or inconvenience.
         Parc y Scarlets' training pitch requires
       watering three times a day, with the irrigation
       pumps drawing water from the mains and
       running for four to six hours during that period.
       The pumps are speed controlled using a single
       ABB drive, installed by an irrigation company
       several years ago. The irrigation system
       features a valve control system which opens
       sprinkler heads on the pitch, allowing a
       measured supply of water which can be
       changed based on the condition of the pitches.
         Rather than programming the VSD to power
       down when not needed, APDS used a PID
       macro with the drive’s sleep function. Thus,
       when all the sprinklers were closed, the system
       reached a set point for pressure and went
       sleep, ready to spray again at a moment’s
       notice.
         However, when a leak was detected in the   that ground staff no longer need to visit during
       under-pitch pipework, the system was unable to   inconvenient hours to manually stop the drives.
       reach the required pressure set point to trigger the   An additional benefit is that the VSD reduces the
       sleep function. With no spare outputs on the   amount of water waste as the RTC switches the
       sprinkler system, the VSD ran continuously, even   system off at the correct time, while the pumps no
       though the irrigation cycle had finished, causing the   longer run dry when the water runs out, prolonging
       pumps to run dry and frequently burn out. Ground   their lifetime.
       staff would have to turn the systems off manually   Luke Jenkins, Scarlets’ Head Groundsman, was
       late at night and at weekends, which was highly   pleased with APDS’ intervention: “Having to come
       inconvenient.                        in late at anti-social hours was really frustrating and
         Digging up the pitch to locate and fix the leak   spoilt many a family dinner. Using the drive to fix
       was costly and would impact on the team’s ability   the problems may only be a temporary stop gap,
       to train, and potentially affect team performance   but it at least means the ground staff can get our
       throughout the duration of the work. As a   lives back. APDS had fixed the problem within 24
       temporary, yet quicker and cost-efficient solution,   hours of our enquiry, so we were extremely pleased
       APDS used the VSD’s onboard real time clock (RTC)   with the speed of their response, and thanks to their
       to stop and start the sprinkler system.   efforts we’ve had no issues with the irrigation
         While permanently fixing the leak will mean that   system since.”
       the pitch is dug up, this short-term solution ensures   www.abb.com

                           August 2021 • INDUSTRIAL TECHNOLOGY EXTRA • p5