Installation and





       care of hygienic




       latch fasteners





       THE EXPERTS AT EMKA OFFER GUIDANCE ON
       THE SPECIALISED AREA OF INSTALLATION AND
       CARE OF HYGIENIC HARDWARE IN ENCLOSURES.

             mka IP69K stainless steel
             hygiene compression latches
             with rounded/double flat or
       Etriangular key inserts are
       EHEDGE Certified to make equipment                                                                          Certifi ed to:
       in food processing and other hygiene
       areas more secure against unauthorised                                                                       IATF 16949
       access. They are specially engineered to                                                                      ISO 9001
       offer tamper and vibration resistance for
       most industrial installations and are   The assembly of the Hygienic
       able to withstand frequent high   quarter turn takes place in a defined
       pressure washes where appropriate.   sheet metal cutout. In order to
         However, Emka points out that   guarantee the tightness of the quarter
       correct installation and care in use is   turn, it must be installed on a smooth
       important for long term effective service   surface and shoud only be operated
       of this type of quarter turn latch   with a special operating key so as not to
       fasteners. In order to minimise   damage the surface.               Remove bottlenecks
       vulnerability to bacterial build up   When installing the Hygienic quarter
       especially in food processing areas   turn, make sure that its axis of rotation
       Emka Hygiene latches have a highly   is not perpendicular to the installation   and simplify your
       polished stainless steel surface and   surface so that it is actuated from
       rounded design.              above. In addition, when the rotary axis
         Care in correct orientation during   is installed horizontally, the quarter turn   processes
       installation  enables  water  and   must be aligned in such a way that in
       contaminants to drain off easily, so   the closing position, the key surface
       reducing accumulation, while use of a   does not form a horizontal surface at
       special hard plastic key prevents   the actuation.
       damage to the lock surface, where   The Hygienic quarter turn must be
       scratches from a metal key could   checked regularly for possible damage
       otherwise offer a site for bacterial    to the surfaces and the seal, as well as
       build up.                    for a backlash-free fit of the actuation. If
         In assembling such a lock to an   damage is found, the quarter turn or the
       enclosure door, it is also important to   flat gasket must be replaced.
       ensure that it is fitted to a sufficiently   The hygienic quarter turn should be   Make your adhesive and dispensing processes more
       smooth  surface  and  regularly   cleaned after installation or before initial   productive with process-optimising materials & systems
       cleaned/maintained in order to preserve   commissioning, and then as required
       integrity of the gasket and it’s seating.   (depending on the degree of soiling), or   •   Improve speed and accuracy   •   Get fast, homogenous mixtures
         So let’s look at some of the   at regular intervals (according to your   of dispensing with dedicated   of liquids, powders and pastes
                                                                           dispensing robots            with mixing and degassing
       specifics. The hygienic quarter turn is   internal cleaning plan).                               machines
       intended for closing closed housings   Emka recommends that you clean   •   Reduce work in progress with
       and machine casings of food processing   the hygienic quarter turn manually with   fast UV light curing materials  •   Achieve more consistent
       machines and equipment.      a soft cloth, sponge or brush. Before   •   Improve process simplicity with     bonding results with plasma
         The hygienic quarter turn is suitable   cleaning, make sure that the utensils to   process-convenient materials   surface treatment
       for use in the temperature range from    be used are clean. Be particularly   packaging
       -30°C to +120°C. The outside,   careful when cleaning the gasket and do   Could you reach your productivity potential by improving some
       consisting of actuator and seal, is   not apply excessive pressure. Do not   of these areas? Read more at intertronics.co.uk/productivity.
       suitable for use in the food industry. The   use brushes or other cleaning utensils
       rear side of the hygiene sash cam is not   that damage the surface or cause   01865 842842
       suitable for use in areas where hygiene   corrosion.
       and easy cleaning are required.   MORE INFORMATION: www.emka.com   info@intertronics.co.uk