Page 48 - Saralyn Chu_Portfolio
P. 48
Pitched Roof Build-up
2
u = 0.18 W/m K
0 3 SCULP TURE WORK SHOP & GALLER Y
Portal Frame structure
Purlins spanning between rafters
Steel Profi led Roo f Deck
seal joints to act as VCL
FOUND A TION T O R OOF DET AIL // POR T AL FRAME S TRUCTURE 1 80mm Rockwool Insulation Slab
Steel Brackets, Rail and Halters
EXPL ODED S TRUCTURE IN AX ONOMETRIC Steel Profi le Metal Deck
Eaves Gutter
lined with Aluminium with
Bituminous Liner, torch jointed
RF Eaves RF Eaves
+8.135 +8.135
22mm Fascia Board
Projection from Column as Eaves Beam
Aluminium Soffit
Ventilated Cavity
Ventilated Horizontal Cavity Barrier
as Cavity Closer
EPDM strapped to window frame
First Floor Build-up and fully bonded to CP Sheathing
To achieve Minimum 60min Fire Resistance Rw
Acoustic Resistance Double Glazed Aluminium Window unit
2
max u-value 1 .0W/m K
22mm T&G Engineered Timber Floor Deck
15mm Grooved Underfloor Heating Underlay Tray wtih Aluminium Profiled cill unit
12mm Heating Pipes
Insulation for Underfloo r Heating System
150mm Composite Metal Deck comprising of
Infi ll Concrete with reinforcements
Steel Profi le
Spanning between Ventilated Horizontal Cavity Barrier
Primary Steels as Cavity Closer
Allow for 300ø openings in Castellated Beam for ventilation path
LIVE L O AD Service void
Metal Frame Ceiling System with Ventilated Horizontal Cavity Barrier
2x12.5mm FireLine Drylining for Steel Protection with Intumescent strip for 25mm Cavity
1 00mm insulation 30min Fire Resistance
at First Floor
01 FFL 01 FFL
+4.623 +4.623
External Wall above DPC build-up
2
u = 0.18 W/m K
2x 12.5mm Plasterboards
150mm infi ll s ystem comprising of
Studs @ Max 600 c/c
and Window head and sill track
Base Track
Slotted Head
track
DE AD L O AD
150mm Full Fill Rockwool Steel Frame Slab insulation
12mm Sheathing
150mm Rockwool Rainscreen Slab
Tyvek Firecurb Fire Resistant Breather Membrane
Outline of 25mm Ventilated Cavity
Steel Column Casing system beyond
to achieve 60min Fire resistance to Steel Column
"Helping Hand Bracket" Concealed Fixing System for 175mm Projection
8mm Corten Steel Panel Cladding as fi nishing; 1 0mm Gaps between
Dress DPM up DPC Painted Kicker Block Ventilated Horizontal Cavity Barrier
as Cavity Closer
Painted Softwood Skirting
EPDM strapped to window frame
and fully bonded to CP Sheathing
Ground Floor Build-up Double Glazed Aluminium Window unit
2
max u-value 1 .0W/m K
4mm Epoxy Resin with Top Coat Aluminium Profiled cill unit
75mm Screed with
Underfloor Pipe Routing Ventilated Cavity
DPM as Seperating Layer
75mm Insulation
DPM above slab Ventilated Horizontal Cavity Barrier
150mm Ground Bearing Slab with Mesh as Cavity Closer
Geotextile for RC Casting
Min 150mm Compacted Hardcore Ventilated Horizontal Cavity Barrier
with Intumescent strip for 25mm Cavity
30min Fire Resistance
Aluminium Flashing
with front drip detail as
Cavity Tray
GF FFL GF FFL
±0.000 ±0.000
External Wall Below DPC Build-up
2x 12.5mm Plasterboards
140x440mm Kicker Block
painted DPC
12mm Sheathing
60mm Rockwool Rainscreen Slab
50mm Unventilated Cavity
Engineer Brick Leaf in Stretcher Bond upto DPC level
with min M12 strength Mortar
Section A-A
1
scale 1:20 @ A1
1:40 @ A3
SCALE
1:20 @ A1
1:40 @ A3 0.8 1.6 2.4m