Page 54 - MKRS Ring lock User Guide Manual Blue Redesign PDF_Neat
P. 54

RINGLOCK

                       TECHNICAL MANUAL


                      Ringlock Certification—Rosette Connection







                                       COMPONENT CAPACITIES- SAFE WORKING LOADS
                               When RINGLOCK components are used together with components of a compatible
                             system, all safe working loads are to be limited to the system with the lowest capacity.
                           Rotational moment



                                                                    M = ± 0.39 kNm



                           Connection moment




                                                                    M = ± 1.05 kNm


                           Direct force




                                                                    F = ± 23.9 kN



                           Horizontal force (O-type)




                                                                    F = ± 10.80 kN



                           Horizontal force (U-type)



                                                                    F = ± 3.95 kN



                           Vertical force




                                                                    F = ± 18.5 kN




                           To accompany certificate number:












            54