Iodine vapors give brown spots on a yellow back-ground with most organic                                 .5
                                          substances especially unsaturated compounds.                   .6

Radioactive materials can be detected by autoradiography or by special
                                                                                            scanners.

                                   4. Evaluation and Analysis.

Rf values (rate of flow) Rf values give idea on the rate of mobility of substances in
a particular system. Although Rf values are not always reproducible, they give idea

                                      on the relative mobility of the separated substances.

Distance traveled by the center of the zone from starting point

R=   ____________________________________________________________________________

  f

Distance simultaneously traveled by the developing solvent.

     ac                  sas
           b

     Rfa =  a  Rfb =  b  Rx =s  a
            c         c         s

Unlike Rf values, Rst values may bFeig. 9g: Rref aandtRexrvatluhesa. n one. Rst values should be within
                                 0.5 to 1.5, otherwise a different standard should be used.

     Distance moved by the substance

     R=     ______________________________________________

       st

     Distance moved by the standard (X)

                                                                                   Tailing in TLC

Instead of ideal round resolved spots, tailed or comet like spots appear.
Accordingly, sample components overlap and hence clean separations are not