Lofts shall be not less than  feet (, mm) in any horizontal
                   dimension.
 NEW CODE FOR SITE  Portions of a loft with a sloped ceiling measuring less than  feet
                   AQ104.1.3 Height effect on loft area.
                   ( mm) from the nished oor to the nished ceiling shall not be
                   considered as contributing to the minimum required area for the loft.
 BUILT TINY HOUSES  Exception: Under gable roofs with a minimum slope of  units vertical
                   in  units horizontal ( percent slope), portions of a loft with a sloped
                   ceiling measuring less than  inches ( mm) from the nished oor
                   to the nished ceiling shall not be considered as contributing to the
                   minimum required area for the loft.
                   AQ104.2 Loft access.
                   The access to and primary egress from lofts shall be of any type
                   described in Sections AQƒ.. through AQƒ...
                   AQ104.2.1 Stairways.
                   Stairways accessing lofts shall comply with this code or with Sections
                   AQƒ... through AQƒ....                                                                      SOURCE: INTERNATIONAL CODE COUNCIL®
                   AQ104.2.1.1 Width.
                   Stairways accessing a loft shall not be less than „ inches ( mm)
                   in clear width at or above the handrail. The width below the handrail
                   shall be not less than ƒ inches (ƒ† mm).
                   AQ104.2.1.2 Headroom.
                   The headroom in stairways accessing a loft shall be not less than
                   ‡ feet  inches (,††ƒ mm), as measured vertically, from a sloped   New rules. A tiny house floorplan compliant with IRC 2018 space restrictions.
                   line connecting the tread or landing platform nosings in the middle
                   of their width.                                         rungs. Ladders shall be capable of supporting a ƒƒ-pound („ kg) load
                   AQ104.2.1.3 Treads and risers.                          on any rung. Rung spacing shall be .„ uniform within /inch (. mm).
                   Risers for stairs accessing a loft shall be not less than „ inches    AQ104.2.2.2 Incline.
                   („† mm) and not more than  inches (ƒ mm) in height. Tread   Ladders shall be installed at „ƒ to †ƒ degrees from horizontal.
                   depth and riser height shall be calculated in accordance with one of
                   the following formulas:                                 AQ104.2.3 Alternating tread devices.
                    . The tread depth shall be ƒ inches (ƒ† mm) minus four-thirds   Alternating tread devices accessing lofts shall comply with Sections
                     of the riser height.                                  R.„.. and R.„... The clear width at and below the handrails
                    . The riser height shall be  inches († mm) minus three-fourths   shall be not less than ƒ inches (ƒ† mm).
                     of the tread depth.                                   AQ104.2.4 Ships ladders.
                   AQ104.2.1.4 Landing platforms.                          Ships ladders accessing lofts shall comply with Sections R.„.. and
                   The top tread and riser of stairways accessing lofts shall be   R.„... The clear width at and below handrails shall be not less than
                   constructed as a landing platform where the loft ceiling height is   ƒ inches (ƒ† mm).
                   less than ‡ feet  inches (,††ƒ mm) where the stairway meets the   AQ104.2.5 Loft guards.
                   loft. The landing platform shall be † inches to  inches („ to    Loft guards shall be located along the open side of lofts. Loft guards
                    mm) in depth measured from the nosing of the landing platform   shall be not less than ‡ inches ( mm) in height or one-half of
                   to the edge of the loft, and ‡ to † inches (ƒ‡ to „ mm) in height   the clear height to the ceiling, whichever is less.
                   measured from the landing platform to the loft oor.    SECTION AQ105
                   AQ104.2.1.5 Handrails.
                   Handrails shall comply with Section R.„.†.           EMERGENCY ESCAPE AND RESCUE OPENINGS
                   AQ104.2.1.6 Stairway guards.                            AQ105.1 General.
                   Guards at open sides of stairways shall comply with Section R..  Tiny houses shall meet the requirements of Section Rƒ for
                                                                           emergency escape and rescue openings.
                   AQ104.2.2 Ladders.                                      Exception: Egress roof access windows in lofts used as sleeping
                   Ladders accessing lofts shall comply with Sections AQƒ.. and   rooms shall be deemed to meet the requirements of Section Rƒ
                   AQƒ...                                              where installed such that the bottom of the opening is not more than
                   AQ104.2.2.1 Size and capacity.                           inches (,„ mm) above the loft oor, provided the egress roof
                   Ladders accessing lofts shall have a rung width of not less than  inches   access window complies with the minimum opening area requirements
                   (ƒ mm), and ƒ-inch ( mm) to -inch (‡ mm) spacing between   of Section Rƒ...


                   www.greenbuildermedia.com                                              November/December 2018 GREEN BUILDER  45




          13-46 GB 1118 Tiny Houses.indd   45                                                                                  10/25/18   2:19 PM
   42   43   44   45   46   47   48   49   50   51   52