Page 20 - C:\Users\LENOVO\Documents\Flip PDF Professional\
P. 20
KALIBRASI BUKAAN PINTU COLD BIN
Satker : Pelaksanaan Jalan Nasional Wilayah I Provinsi Jambi
Paket : Preservasi Jalan Sp. Tuan - Bts. Kab. Muaro Jambi - Sp. Tiga Batara Gas Plant
: (Pematang Lumut) - Kuala Tungkal dan Jalan Dalam Kota Kuala Tungkal.
Penyedia Jasa : PT. Abun Sendi
Konsultan : PT. Progresia Aditya Pratama KSO. PT. Guteg Harindo
Persen (%) Terhadap Kapasitas AMP Berat Individu Bukaan Pintu
No. Fraksi
Total Agregat Total Campuran ( Ton / Jam ) ( Ton ) ( Cm )
1 Coarse Aggregate 34.00 32.06 40.00 12.82 8.00 0
2 Medium Aggregate 25.01 23.58 40.00 9.43 11.30 0
3 A b u B a t u 25.01 23.58 40.00 9.43 14.90 0
4 Pasir 14.00 13.20 40.00 5.28 7.30 0
5 Filler (Semen) 2.0 1.88 40.00 0.75 -
6 Aspal 5.70 40.00 2.28 - 0
TOTAL 100.00 40.00
PENYEDIA JASA KONSULTAN : BINA MARGA :
RAHMAT RIDUAN HARUN ARONI
Quality Control Lab Technician Nip. 196608222006041003