Step 2: 5 The loca on is not prone to 2 Locate the water heaters
Verify that the loca on physical damage by vehicles, circuit breaker and turn it OFF
(or remove the circuits
ooding, or other risks.
is appropriate fuses).
On the old water heater,
Before installing your water heater, 3
ensure that: remove the electrical
junction box access panel.
Vehicle Using a non-contact circuit tester,
The water heater will be: Stop
1 Installed indoors close to check the wiring to make certain the
the center of the plumbing Drain Drain power is OFF.
system. Pan WARNING! Working on an energized
Figure 8 - In a garage, install a vehicle stop
In a suitable drain pan piped to an to avoid water heater damage. circuit can result in severe injury or
adequate floor drain or external death from electrical shock.
to the building (Figure 6 on page 6 Avoid loca ons such as a cs, Disconnect the electrical
8). upper oors, or where a leak 4 wires.
might damage the structure
In an area that will not freeze or furnishings. Due to the normal Open a hot water faucet and
In an area that is suitable for install- corrosive ac on of water, the tank will 5 let the hot water run un l it is
ing the water heater vertically eventually leak. To minimize property cool (This may take 10
damage from leaks, inspect and minutes or longer).
The loca on has adequate maintain your water heater in accor-
2 space (clearances) for periodic dance with this manuals instruc ons.
servicing. Install a suitable drain pan under the INSTALLATION
water heater piped to an adequate
The oor can support the drain. Inspect the drain pan, pipes, and
3 weight of a full water heater. surrounding area regularly and x any
leaks found. Drain pans are available at
Your area is not prone to your local plumbing supplier. Leaks are
4 earthquakes. If it is, use frequently in the plumbing system
special straps as required by itself and not the water heater.
local building codes. Figure 9 - Let the hot water run until it is cool.
NOTICE: The state of California re- Step 3: WARNING! Be sure the water runs
quires bracing, anchoring, or strapping Removing the old water cool before draining the tank to reduce
the water heater to avoid its moving the risk of scalding.
during an earthquake. Contact local heater 6 Connect a garden hose to the
u li es for code requirements in your Read each installa on step drain valve and place the
area, visit h p://www.dsa.dgs.ca.gov, 1 and decide if you have the other end of the hose in a
or call 1-916-445-8100 and request necessary skills to install the drain, outside, or a bucket. (Note that
instruc ons. Other loca ons may have water heater. Only proceed if you can sediment in the bo om of the tank
similar requirements. Check with your safely perform the work. If you are not may clog the valve and prevent it
local and state authori es. comfortable, have a qualied person from draining. If you cant get the
tank to drain, contact a qualied
perform the installa on. person.)