INSTALLATION




                                                 Step 9:

                                                  Make electrical

                                                connec  ons
                                                   WARNING! Working on an ener-
                                                gized circuit can result in severe injury
                                                or death from electrical shock.

                                                NOTICE: Do not turn electrical power
              NOTICE: The tank must be com-     on unless you are sure all of the air is
              pletely empty of air and full of   out of the tank and the tank is com-
              water before connec  ng electri-  pletely full of water. If power is applied   Figure 18 - The water heater’s electrical
              cal power to avoid “Dry Firing.”   before the tank is completely full of   requirements can be determined from the
              Dry Firing may result in the upper   water, the upper element will burn out   data plate.
              element burning out.  This is a   (Dry Fire).                            5    Install wiring in an approved
              common installa  on mistake. Af-                                              conduit (if required by local
              ter you make the water connec-           Be sure the electrical power to      codes). Use a UL listed or CSA
               ons, but before you connect the    1    the water heater is turned    approved strain relief to secure the
              electrical power, open a hot wa-         OFF at the circuit breaker    electrical wiring to the water heater.
              ter faucet and let the water run   panel (or remove the circuit’s fuses).  6  Connect the ground wire to
       INSTALLATION  three minutes or longer before   2  tester, check the wiring to   power wires to the water heater’s two
              full un  l all the air is removed.
                                                                                            the green ground screw.
                                                       Using a non-contact circuit
              Let the “hot” water run full for
                                                                                            Connect the home’s two
                                                       make certain the power is OFF.
              connec  ng any electrical wires. A
                                                                                     power wires. Use suitable wire nuts or
              Dry Fired upper hea  ng element
                                                                                     other approved means to make the
                                                       Check the water heater’s data
                                                  3
              is an installa  on error and is not
                                                                                     power connec  ons.
                                                       plate and ensure that the
              covered under warranty.
                                                       home’s voltage, wiring size
              If Dry Firing occurs, replace the   (ampacity) and circuit breaker ra  ng
              upper hea  ng element according   and type are correct for this water
              to the instruc  ons on page 22.   heater. Refer to the wiring diagram
                                                located on the water heater for the
                                                correct electrical connec  ons. Ensure
                                                that wire sizes, type, and connec  ons
                                                comply with all applicable local codes.
                                                In the absence of local codes, follow
                                                NFPA-70 and the current edi  on of the
                                                Na  onal Electric Code (NEC).
                                                       Remove the cover on the
                                                  4    electrical junc  on box on the   Figure 19 - Connecting the electrical wires.

                                                       top of the water heater.














             14 • Residen  al Electric Water Heater Use and Care Guide