Page 104 - millerwelds catalog_2022
P. 104

A FLE22 Cat P 104 Safety.qxp_Fume  1/20/22  7:53 PM  Page 1





                     Welding Safety and Health


                           ®
              FILTAIR  MWX Series and Capture 5                                                   Processes
                                                                                                  Stick (SMAW)   Flux-cored (FCAW)
              See literature AY/3.0 (MWX) and AY/3.5 (Capture 5)                                  MIG (GMAW)   TIG (GTAW)
              Mobile fume extraction systems easily positioned near the weld area and designed specifically   Comes with
                                                                                                  FilTek® XL filter
              for welding. Disposable or self-cleaning filter models for multiple applications.   Pre-assembled arm
                                                                                                  Most popular consumables

                                                           Features common to all models

                                                           Source capture. Designed to draw weld fume

                                                           away from the welder’s breathing zone and keep
                                                           the facility clean.
                  MWX-S (self-cleaning filter)
                    model shown with                       Superior filters. The MERV 15 rating of our
                   10 ft. extraction arm.                  FilTek XL filters provides superior filtering of up
                                                                                                  Replacement FilTek XL Filters
                                                           to 95 percent of weld fume particulate.   300540  For MWX (self-cleaning)
                                                           Class-leading suction power of 875 cfm (MWX)   300539  For MWX (disposable)
                                                                                     ™
                                                           or 900 cfm (Capture 5) is Accu-Rated  at the   301106  For Capture 5 (self-cleaning)
                                                                                                  Filters efficiently capture the smallest
                                                           hood to better capture weld fumes and provide a
                                                                                                  weld fume particles and offer superior
                                                           cleaner environment.
                                                                                                  filter life
                                                           Note: Accu-Rated is the true, accurate airflow at the inlet of the
                                                           collection hood.                       Most popular accessories
                                                           Durable aluminum pre-assembled extraction
                                                           arm with external adjustments for better airflow
                                                           and longer life.
                                                           Self-cleaning models additional features
                                                           Upgrade to self-cleaning models for high arc-on
                                                                                                  Hood Light with Arc Sensor
                                                           time, extracting from heavy fume processes, or
                                                                                                  300689  For MWX Series
                                                           when welding aluminum or galvanized materials.
                                                                                                  Illuminates the welding zone and
                                                           Excellent filtering performance. Weld fume   enables the fume extractor to start
                                                           particulate is captured with a self-cleaning    automatically when welding begins
                                                           filter and safely deposited in an integrated
                                                           particulate bin.
                                                           Quick and efficient cleaning cycle operates
                                                           with a push of a button on the control panel to
                                                           clean the filter from the inside out.
                     Capture 5 shown with                  Note: Compressed air required to operate cleaning mechanism.
                       12 ft. ZoneFlow
                       extraction arm.                     Disposal drawer provides easy and convenient
                                                           access to empty out collected particulate.
                                                           Handle releases drawer allowing it to slide out.

                                                           Capture 5 model additional features
                                                           EXCLUSIVE! ZoneFlow  technology. Extends
                                                                           ™
                                                           the capture zone up to five feet versus up to
                                                           18 inches with conventional source capture
                                                           arms. See page 106 for more information.
                                                           Minimizes downtime with fewer fume extractor
                                                           adjustments. With increased capture area,
                                                           arm interactions are minimized.




                                                       Accu-Rated ™    Extraction
              Model/Stock Number              Filter Media   Airflow   Arm Diameter   Sound Level   Motor   Input Power   Dimensions   Net Weight
              MWX-S (Self-Cleaning)   MWX-D (Disposable Filter)   490 sq. ft.   875 cfm   8 in.    Approximately   1 hp,   115 V, 1-phase,    H: 34.75 in. (883 mm)   MWX-S:
              (951510) 7 ft. standard arm   (951507) 7 ft. standard arm   (45.52 sq. m)   (413 L/sec.)   (203 mm)   70 dBA at    3,450 rpm   60 Hz at   W: 31.75 in. (806 mm)   300 lb. (136 kg)
              (951511) 10 ft. standard arm  (951508) 10 ft. standard arm            5 ft. (1.5 m)      approximately 11.9 A   D: 48 in. (1,219 mm)   MWX-D:
              (951512) 12 ft. standard arm  (951509) 12 ft. standard arm                                         238 lb. (108 kg)
              Capture 5 (Self-Cleaning)       452 sq. ft.    900 cfm   10 in.    Approximately   3 hp,   208/230 V, 1-phase,   H: 43 in. (1,092 mm)   660 lb. (300 kg)
              (951639) 208/230 V, 10 ft. ZoneFlow arm   (42 sq. m)  (425 L/sec.)  (254 mm)  77 dBA at    3,450 rpm  60 Hz at 13.5 A   W: 36 in. (915 mm)   with 12 ft. arm
              (951640) 208/230 V, 12 ft. ZoneFlow arm                   5 ft. (1.5 m)  460 V, 3-phase,    D: 48 in. (1,219 mm)
              (951574) 460 V, 10 ft. ZoneFlow arm                                      60 Hz at 13.7 A
              (951575) 460 V, 12 ft. ZoneFlow arm
              104
   99   100   101   102   103   104   105   106   107   108   109