Page 156 - KA Sensors 2020 Motorsport Catalog_Neat
P. 156

Sub-Miniature High Precision Pressure Scanner
              Specification                  Specification Continued                       Options



     Specification (P16 Version)          Environmental Conditions
     Inputs (Px)                                                               •     CANbus to USB adapter complete with
                                          Operating Temperature:
     16 x 0.040"                                                                     software interface
                                          -40 to 240°F
     Full Scale Ranges:                   Vibration:                           •     Full range of tubes, connectors and
     Any range can be specified between 3 psi and 17 psi   9G/1000Hz (24 hr)         extension cables
     Absolute or Differential*                                                 •     Special ranges/calibrations
     For example: 5 to 15 psi Absolute    Communication Interface
     Accuracy:                            CANbus standard
     For Absolute: 0.1% FS                CAN/USB Adapter, optional
                                          Data Output Rate:
     For Differential: 0.2% FS
     Includes non-linearity, hysteresis and repeatability   Variable up to 1000Hz/Channel
     Proof pressure:                      Power:
     85 psi                               9-24 VDC
     Resolution:                          Current Consumption:
     0.00015 psi (0.00045 psi at 1000Hz)   <30mA
     Long Term Stability:                 Electrical Connector:
     <0.015 psi/year                      Deutsch, Harwin, Lemo or Flying lead (no connectors)
                                          Weight:
     Construction                         <0.6oz
     Wetted parts:                        Dimensions:
      Stainless steel/Aluminum/Polyetherimide (PEI)   1.4 x 1.3 x 0.36"

     Outer case:                                                               * Please consult factory for Differential ranges
     Carbon Fiber
     Tubulations:
     Stainless Steel 304
     Media:
     Clean Dry Air- avoid liquid contaminants
         Ordering Information



                                                                                                    Special
      EvoScann°  Measurement  Channels   Mode:     Range:   Comms:  Cable:   Connector:   Calibration:
                                                                                                    Instructions:
                 P-Pressure   16A       A-Absolute   X - X   A-CANbus   12"   A-None     A-Standard   A-None
                                        B-Differential*     X-Other   20"    B-Deutsch   X-Other    X - Check
                                        X-Other                      40"     C-Lemo                 Notes
                                                                     X  - Custom  D-Harwin
                                                                             X-Other
     PMC Engineering adopts a continuous development program which sometimes necessitates specification changes without notice


                                                      Mechanical Details


              Dimensions in inches
                                                                                      P16










                                                                                              1.3"





                                   1.4"                                               0.36