Sub-Miniature High Precision Pressure Scanner
Specification Specification Continued Options
Specification (P64D Version) Environmental Conditions
Inputs (Px) • CANbus to USB adapter complete with
Operating Temperature:
64 x 0.040" software interface
15 to 200°F
Full Scale Ranges: Vibration: • Full range of tubes, connectors and
±100 mbar to ±200 mbar (±1.5 psi and ±3 psi) extension cables
9G/1000Hz (24 hr)
Contact factory for additional ranges up to 15 psi • Special ranges/calibrations
Accuracy: Communication Interface • FIA Homologated
Differential: 0.5% FS Direct CANbus optional
Including non-linearity, repeatability and hysteresis CAN/USB Adapter
Overpressure Capability: Data Output Rate:
5x calibrated range Variable up to 500Hz/Channel
Resolution: Power:
0.003 mbar@ 100 mbar range 9-24 VDC
0.006 mbar @ 200 mbar range Current Consumption:
Drift: <70mA
<1 mbar / year Electrical Connector:
Construction Deutsch
Weight:
Wetted parts: 3.9oz
Stainless steel/Aluminum/Viton® Dimensions:
Outer case: 2.75 (3.15*) x 2.16 x 0.86"
Windform™ SP *includes tubulations
Tubulations:
Stainless Steel 304
Media:
Clean Dry Air- avoid liquid contaminants
Ordering Information
Special
EvoScann° Measurement Channels Mode: Range: Comms: Cable: Connector: Calibration:
Instructions:
P-Pressure 64 D-Differential A - ±100mb ANbus None A-Deutsch A-Standard A-None
A - C
B - ±200mb X-Other X-Other X - Check
Notes
X - Specials
PMC Engineering adopts a continuous development program which sometimes necessitates specification changes without notice
Mechanical Details
Dimensions in inches 0.90"
2.18"
1.3"
0.3"
1.4"
3.11"