550 PLASTICS GLAZING
      • Standard: To BS 5516-2, Annex A.
      • Sheets: Accurately sized with clean, undisfigured and undamaged edges and
          surfaces.
      • Glazing bar edge cover to sheets: Adequate to prevent displacement due to
          thermal movement and flexing under load.
      • Sealing and glazing materials: Compatible with sheets.

560 INFILLING
      • Standard: To BS 5516-1.
      • Sheets: Accurately sized with undisfigured and undamaged edges and surfaces.

575 OPENABLE WINDOWS IN NATURALLY VENTILATED BUILDINGS
      • Location: Over 10 m from sources of external pollution.

RotF generic (intermediate) NBS 2014  6118-AEW-XX-XX-NBS-A-01