Page 27 - McD_6118-AEW-XX-XX-NBS-A-001_Neat
P. 27

COMPLETION

910 DISMANTLING RETENTION STRUCTURE
      • Permanent connections: When complete between façade and new construction,
          give notice.
      • Disconnection and dismantling: Obtain permission before proceeding.

920 REMOVAL OF TEMPORARY FOUNDATIONS
      • Break out : to depths as agreed site specific with Engineer.
      • Backfilling: As section D20.

930 COMPLETION CONDITION SURVEY
      • Timing: After disconnection of support systems, survey and record the state of
          façade.
      • Defects: Ensure that defects caused by or due to retention structure have been
          remedied.
      • Record: Submit for agreement.

940 REPAIRS TO FAÇADE
      • Scope: Remove fixings and make good connection holes.

RotF generic (intermediate) NBS 2014  6118-AEW-XX-XX-NBS-A-01