Page 23 - McD_6118-AEW-XX-XX-NBS-A-001_Neat
P. 23

380 STABILITY LOADS
      • Façade gravity load (Wf): None other than self weight.
      • Supporting structure gravity loads (Ws): Self weight of structure plus all dead and
          imposed vertical loads supported thereon.
      • Design out-of-plumb dimensions: Façade dimensions measured immediately prior
          to erection of the retention structure, plus allowances for deflections due to
          façade foundation and thermal movements, plus calculated deflection due to
          movements of retention structure and its foundations.
      • Lateral load due to offsets/ out-of-plumb (Hp): The force necessary to stabilise the
          façade vertical loads against movement due to offsets and out-of-plumb.
      • Design stability loads: The greater of (Hp plus 1.5% of Ws) or 1.5% of (Wf + Ws).

385 LOADS ON CONNECTIONS
      • Gravity load (Wc): The total gravity load due to self weight of façade and applied
          gravity loads above connection level.
      • Lateral load due to offsets/ out-of-plumb (Hpc): The proportion of load Hp carried
          by the row of connections.
      • Wind load (Hwc): The wind force on the area of façade supported by the row of
          connections.
      • Maximum load on row of connections (Hr): The greater of (2.5% of Wc plus Hwc) or
          (Hpc + Hwc).
      • Maximum load on a connection: The proportion of Hr likely to be carried by the
          connection.

390 VEHICLE IMPACT PROTECTION
      • Design loading: 7.5 kN/m in any direction.
      • Location: Spacing between protection and retention structure/ façade equal to
          barrier working width to BS EN 1317-2.

          PRODUCTS

430 SCAFFOLDING AND ACCESSORIESREPAIRS TO STRUCTURE KEPT IN PLACE
      • Standard: To BS EN 12811-1 and -2.
      • Protective coating for carbon steel tubes and fittings: Protect steelwork and
          prevent rust staining of façade and other permanent or retained works Until
          retention structure is dismantled.

480 LOADBEARING TIMBER WEDGES/ PACKS
      • Species: Straight grained hardwood.
      • Density (minimum): 650 kg/m³.

          EXECUTION

600 WORKMANSHIP
      • Standard: HSE Guidance Note GS51 and To BS 5975
      • Operatives skill and experience: Appropriate for the type of work.
          - Evidence: Submit prior to commencement.

RotF generic (intermediate) NBS 2014  6118-AEW-XX-XX-NBS-A-01
   18   19   20   21   22   23   24   25   26   27   28