Page 316 - McD_6118-AEW-XX-XX-NBS-A-001_Neat
P. 316

K13 Rigid sheet fine linings and panelling

            TYPES OF LINING AND PANELLING

  120 WOOD VENEERED PANEL LINING generally
        • Substrate: site specific.
        • Battens: Softwood free from decay and active insect attack and with no knots
            wider than half the width of the section.
             - Finished size: site specific.
             - Moisture content at time of fixing (maximum): 18%.
             - Spacing (centres): site specific.
             - Method of fixing: Plugged and screwed at 600 mm centres.
        • Panels:
             - Core material: Medium density fibreboard to BS EN 622-5, Type MDF.
               Thickness: 12.
               Fire retardant impregnation treatment: site specific.
               - Face veneer: Free from decay and holes.
               Supplier: site specific.
               Wood species: site specific.
               Cutting: to suit veneer specied.
               Arrangement: site specific.
               - Backing veneer: As recommended by fabricator.
               - Edge treatment: none.
               - Fabrication: As section Z10.
               Adhesive: To BS EN 204; Type: To match durability class of core material.
               - Finish (to match approved sample): Nonintumescing clear finish to give Class 1
               surface spread of flame rating to BS 476.
               - Moisture content at time of fixing: As recommended by fabricator to suit
               environmental conditions.
        • Installation:
               - Method of fixing panels: concealed.
               - Joint treatment: biscuited but joints, 1mm V.
        • Included features: site specific.
        • Accessories: site specific.

RotF generic (intermediate) NBS 2014  6118-AEW-XX-XX-NBS-A-01