Page 338 - McD_6118-AEW-XX-XX-NBS-A-001_Neat
P. 338

680 INSTALLING BOARDS
      • Fixing boards to grids: Screw boards securely and firmly to grid members.
      • Surface: Provide a flat surface free from bowing and lipping. Set heads of screws
          below surface of boards and fill flush with surface.
      • Movement joints: Provide as appropriate for the area of ceiling and align with
          movement joints in surrounding structure.
      • Boards applied in two or more layers: Stagger joints.
      • Board edges: Fully support. Screw to grid members.

700 COORDINATION WITH SERVICES
      • Preparation: Check existing position of services against proposed alterations.
      • Clashes between services and ceiling system: Give notice.
      • Coordination: Programme works to minimise impact.
      • Services disconnection: Give notice.

710 INTEGRATED SERVICES
      • General: Position services accurately, support adequately. Align and level in
          relation to the ceiling. Alterations must not diminish performance of ceiling system.
      • Surface spread of flame rating of additional supporting material: Match ceiling
          material.
      • Services outlets:
          - Supported by ceiling system: Provide additional hangers.
          - Independently supported: Provide flanges to support altered ceiling system.

715 LUMINAIRES
      • Independently support luminaires: Adjust suspension to line and level of ceiling as
          necessary.
      • Surface mounted luminaires: Do not inhibit designed grid expansion in fire.
      • Modular fluorescent recessed luminaires: Compatible with ceiling module.
          Extension boxes must not foul ceiling system.
      • Continuous recessed rows of luminaires: Provide flanges for support of grid and infill
          units, unless mounted above grid flanges. Retain in place with lateral restraint.
      • Fire protecting and resisting ceiling systems: Luminaires must maintain protection
          integrity of ceiling system.
      • Access: Provide access for maintenance of luminaires.

720 MECHANICAL SERVICES
      • Fan coil units:
          - Inlet and outlet grilles: Trim ceiling grid and infill units to suit.
          - Void clearance beneath: Sufficient for ceiling system and fan coil components.
          - Suspension and connections: Permit accurate setting out and levelling of fan coil
             units.
      • Air grilles and diffusers:
          - Linear air diffusers: Provide flanges for support of grid and infill units. Provide for
             displacement of ceiling grid. Retain in place with lateral restraint.
          - Grille and diffuser ceiling joints: Provide smudge rings and edge seals.

 725 OTHER SERVICES                                     6118-AEW-XX-XX-NBS-A-01
       • Smoke detectors and PA speakers:
              - Infill units: Scribe to suit.
              - Flexible connections: Required.
       • Sprinkler heads: Carefully set out and level.

RotF generic (intermediate) NBS 2014