Page 44 - McD_6118-AEW-XX-XX-NBS-A-001_Neat
P. 44

C45 Damp proof course renewal/ insertion

  110 PRECONTRACT SURVEY
        • General: A survey has been carried out and the report is available for inspection.
        • Survey limitations: Areas not surveyed as identified in report.

  115 SURVEY AND REPORT
        • Survey generally:
             - Purpose: To confirm presence and extent of rising damp and suitability of walls
               for treatment by the proposed dpc system.
             - Timing: Before starting dpc installation work carry out survey and submit survey
               report.
             - Location of drilled samples: Submit proposals.
        • Survey report content:
             - Extent of rising damp: Determine using methods recommended in the Property
               Care Association Code of Practice 2 'Code of practice for the installation of
               remedial damp proof courses in masonry walls', clause 6.
             - Proposals: Submit levels and positions of horizontal and vertical dpcs.
             - Associated work: Nature and extent of repair and/ or replacement work required
               to ensure an effective dpc.
             - Limitations: Identify areas where a full survey could not be carried out.
             - Other information: Any considered relevant.

  135 ASSOCIATED WORK
        • Work shown to be necessary by the survey: site specific.

  140 BEFORE DPC INSTALLATION
        • Positions of dpcs not shown on drawings: Submit proposals.
        • Internal finishes: Remove only sufficient to expose the proposed line of dpc.
        • Fungal or beetle attack to timber sections: Report occurrences.

  150 REMOVAL OF EXTERNAL RENDER
        • Extent of removal (maximum): 100 mm above proposed dpc level.

  165 REPOINTING OF WALLS
        • Location: On line of proposed dpc.
        • Timing: Before installation of chemical injection dpcs.
        • Mortar: As section Z21.
             - Mix: site specific.

  220 CHEMICAL INJECTION DPC SYSTEM
        • Manufacturer: Contractor's choice.
             - Product reference: Contractor's choice.
        • Installation: To BS 6576 by a firm approved by the dpc system manufacturer.

RotF generic (intermediate) NBS 2014  6118-AEW-XX-XX-NBS-A-01