Page 9 - McD_6118-AEW-XX-XX-NBS-A-001_Neat
P. 9

B12 Conservatories

            GENERAL

  110 CONSERVATORY extensions; site specific
        • Performance:
             - Windows generally: BS 4873.
             - Weathertightness exposure category to BS 6375-1: to suit location.
             - Integrity:
               Wind loading: Calculate in accordance with BS 6399-2.
               Snow loading: Calculate in accordance with BS 6399-3.
               Permanent imposed loads: site specific.
               Temporary imposed loads: site specific.
             - Window operation and strength: To BS 6375-2.
             - Window security: not applicable - fixed lights only.
        • Frame:
             - Material: Aluminium .
             - Frame depth: site specific.
             - Head option: Square head.
             - Finish: PPC.
               Colour: site specific.
        • Roof glazing:
             - Material: Insulating glazing units.
             - Beading:
               Material/ Type: Aluminium capping over glazing bars, powder coated.
               Location: Outside.
        • Wall glazing:
             - Material: Insulating glazed units.
             - Beading: ouside.
               Material/ Type: Aluminium capping over glazing bars, powder coated.
               Location: Outside.
        • Ventilation:
             - Roof vents: None.
             - Wall vents: none.
        • Ironmongery: n/a.
        • Rainwater drainage: Cast aluminium guttering and downpipes, powder coated.
        • Accessories: site specific.

            PRODUCTS

  310 ALUMINIUM ALLOY FRAMING SECTIONS
        • Standard: To relevant parts of BS EN 515, BS EN 573, BS EN 755-9 and BS EN 12020.
        • Alloy, temper and thickness: Suitable for the application and specified finish.
        • Structural members: To BS 8118-2.
        • Thermal breaks in framing: Required.

RotF generic (intermediate) NBS 2014  6118-AEW-XX-XX-NBS-A-01