Page 63 - McD_ROTF DRAINAGE & PIPED SERVICES_Neat
P. 63
Drainage & Piped Services Standard Specification
Version 2014-1
Manufacturer: Submit proposals.
Standard: To BS 4211.
Material: Aluminium, mill finish.
Aluminium, coated.
powder
Integral accessories: Submit proposals. bolts;
and filling;
Access chamber steps type C for filling;
Manufacturer: Submit proposals.
Standard: To BS EN 13101. for
Form: Submit proposals.
Material: Galvanized steel.
Integral accessories: Submit proposals.
Access covers and frames type C
Manufacturer: Submit proposals.
Standard: To BS EN 124.
Form: Double seals grease, lock
Non-rocking; covers
covers
Recessed concrete
pavior
Recessed
and Single seal.
Materials: Ductile cast iron and Grey cast iron.
Finish: Black bitumen painted.
Sizes: Submit proposals.
Loading grades: Submit proposals.
Edging trims: Not required.
Integral accessories: Submit proposals.
Execution
Formation for beddings in below ground drainage monitoring and control systems type A
Timing: Excavate to formation immediately before laying bases or beddings.
Mud, rock projections, boulders and hard spots: Remove. Replace with consolidated bedding material.
Local soft spots: Harden by tamping in bedding material.
Inspection of excavated formations: Give notice.
Formation for beddings in below ground drainage monitoring and control systems type B
Timing: Excavate to formation immediately before laying bases or beddings.
Mud, rock projections, boulders and hard spots: Remove. Replace with consolidated bedding material.
Local soft spots: Harden by tamping in bedding material.
Inspection of excavated formations: Give notice.
Fixing steps in below ground drainage monitoring and control systems type A
Fixing: Bed in joints.
3 / 31