Page 61 - McD_ROTF DRAINAGE & PIPED SERVICES_Neat
P. 61

Drainage & Piped Services Standard Specification
Version 2014-1

Brick Manhole System for Below Ground Drainage
System Performance: Design of access chambers for below ground drainage type B.
Base slabs: Designated concretes for drainage applications type F.
Walls:

                 Masonry units: Class B engineering bricks
                 Mortar:
                 Support above pipes: Precast concrete lintels.
Preformed channels and benching:
                 Preformed channels: Plastics channels for access chambers type B and Vitrified clay channels
                 for access chambers type B.
                 Benching: Designated concretes for drainage applications type G.
                 Topping: Wearing screed
Reducing slabs:
                 Concrete: Designated concretes for drainage applications type H.
                 Reinforcement: Submit proposals.
Access components: Access chamber ladders type A and Access chamber steps type C.
Covers:
                 Cover slabs:

                         Concrete: Designated concretes for drainage applications type I.
                         Reinforcement: Submit proposals.
                 Seating: Submit proposals.
                 Covers and frames: Access covers and frames type C.
Backfill: Submit proposals.
Execution: Formation for beddings in below ground drainage monitoring and control systems type A;
Formation for beddings in below ground drainage monitoring and control systems type B; Fixing steps in
below ground drainage monitoring and control systems type A; Fixing steps in below ground drainage
monitoring and control systems type B; Laying preformed plastics channels, branches and benching in
access chambers for below ground drainage type A; Laying sealed access fittings, branches and benching in
access chambers for below ground drainage type A; Installing access covers and frames to chambers for
below ground drainage type A; and Installing access covers and frames to chambers for below ground
drainage type B.

System Completion:

System Performance

Design of access chambers for below ground drainage type B

Design: Complete the design of the access chamber system.

Standards: To BS EN 752 and                       in accordance with  National Annex NA;
In accordance with                                          Sewers
In accordance with Sewers                                             for adoption;
and In accordance with Sewers for Scotland.            for adoption,
                                                                      Northern  Ireland;

Products                                          3 / 29

McDonalds Restaurants Ltd
   56   57   58   59   60   61   62   63   64   65   66