Page 150 - B6118-AEW-XX-XX-PP-A-0001_(P19)_Contractors Manual
P. 150
DESIGN
D6 Overview of General Interior Décor Concept Elements
Scotland
Public Toilets
WC provision must be in line with the Technical
Handbook requirement for all projects.
Table 3.8 in section 3.12.5 ‘Provision for public in entertainment & assembly buildings’ of the ‘Environment’ Non Domestic Technical
Handbook states:
Building Type (2) Sex Number of People Number of WCs Number of Urinals
Restaurants, cafes, canteens male 1-400 [6] 1 for every 400, or part 1 for every 50 males, or
and fast food outlets (where thereof part thereof
seating is provided) over 400 plus 1 for each extra 250
Cleaners Sink males, or part thereof
female 1-20 2
21-50 3
51-100 4
101-150 5
151-200 6
over 200 plus 1 for each extra 100
females or part thereof
Employee Toilets
Employee toilet provision must be in line with
the Technical Handbook requirement for all
projects.
Table 3.5 in section 3.12.2 ‘Provision for staff’ of the ‘Environment’ Non Domestic Technical Handbook states:
Gender Staff Numbers WC WHB Urinals
Male 1-5 1 1 1
16-30 2 2 1
31-45 2 2 2
46-60 3 3 2
61-75 3 3 3
76- 90 4 4 3
91- 100 4 4 4
over 100 1 additional WC, WHB and urinal for every additional 50 males or part thereof
Female (also male 1- 5 1 1
where no urinals are 6 - 25 2 2
provided)
over 25 1 additional WC and WHB for every additional 25 females (or males), or part
thereof
D6.13 Toilet Facilities 5.0 10 October 2017