Page 3 - SELECTA • 3M COLD SHRINK SOLUTIONS FOR LOW VOLTAGE
P. 3

3M  Cold Shrink Solutions for Low Voltage
          ™
        EPDM Rubber Cold Shrink Products



                                                                                                Conductor
                           Product           Description                 Applications           Size Range  Cable O.D.
                                                                                                            Range (In.)
                                                               •   Primary electrical insulation for solid
                                                                 dielectric cable splicing up to 1000 volts
                                                               •   Insulation of secondary splices
                         3M  Cold     Cost-effective, general purpose   •   Environmental sealing for communication
                            ™
                                                                 and other non-electrical applications
                         Shrink       cold shrink tubes. One of our   •   Indoor/outdoor use     #10 AWG–
                         Insulators    most commonly used cold shrink   •   Direct bury         2000 kcmil   0.10–3.69
                                      products, these insulators provide
                         8420 Series  a tight, moisture-resistant seal.  •   Submersible
                                                               •   Dig-in repairs
                                                               •   Sheath repairs
                                                               •   Moisture sealing
                                      Cold shrink tubes with built-in
                         3M  Cold     sealing mastic on each end. The   All the same applications as the
                            ™
                                                               8420 Series, plus:
                         Shrink Quick   mastic allows range-taking, so                           #8 AWG–
                         Insulator    fewer parts are needed to cover a   •   Set-screw or oversized connectors  3000 kcmil   0.20–2.75
                                      wider range of cable sizes. It can
                         QI Series    also fill small crevices in the cable   •   Large diameter cables and textured
                                      jacket, ensuring a complete seal.    cable jacket applications
                         3M  Cold     Open-ended tubular rubber
                            ™
                         Shrink Quick   sleeve with sealing mastic on    All the same applications as the
                                                               QI Series, plus:
                                      each end. A built-in solid plastic
                         Splice Low   core provides center structural                            #8 AWG–
                         Voltage      support and protects against   •   Applications requiring extra    500 kcmil   0.20–1.60
                         QSLV-M       puncture from rigid connectors.   structural support
                         Series       Unique twin-core pull helps    •   Connectors with a steep drop off
                                      prevent snagging along the cable.
                         3M  Cold     A thicker tube-wall than standard   All the same applications as the
                            ™
                                      cold shrink tubes accommodates
                         Shrink       up to 2000-volt applications, such   8420 Series, plus:
                                                                                                 #4 AWG–
                         Connector    as wind farm tower connections.                            1500 kcmil  0.35–2.50
                         Insulators    UL listed for direct bury and   •   Wind farm towers
                         WF Series    submersible applications. Tough   •   Insulation for applications up to 2 kV
                                      rubber withstands backfill pressure.
                                      Cold shrink tubes with foam   •   Wireless communications towers
                         3M  Cold     weatherproofing strips to build    •   Exposed coaxial interfaces
                            ™
                         Shrink Kit    up the diameter of one end of a   •   Coaxial cable with Type N or 7/16 DIN   #6 AWG–   0.25–2.25
                                                                                                 1250 kcmil
                         CXS Series   coaxial cable and accommodate    connectors
                                      a wider range of cable sizes.  •   Jumper cable-to-termination connections
                         3M  Cold     Mastic seal strips insulate each
                            ™
                                      individual connection. A copper
                         Shrink       shielding sleeve connects armor                            #14 AWG–
                                                                                                 #4 AWG
                         5730-5731    and builds armor continuity.    •   Armored (Teck-90)                  0.62–1.40
                                                                 3- or 4-conductor cables
                         Series       A large cold shrink tube is                                (individual
                                                                                                  cables)
                         Splice Kits  installed over the entire assembly
                                      to create an insulating splice.
                         3M  Cold     Three small cold shrink tubes seal
                            ™
                                      each individual connection. A
                         Shrink       copper shielding sleeve connects                           #2 AWG–
                                                                                                 750 kcmil

                         5732-5735    armor and builds armor continuity.   •   Armored (Teck-90)             0.95–4.0
                                                                 3-conductor cables
                         Series       Large cold shrink tube is installed                        (individual
                                                                                                  cables)
                         Splice Kits  over the entire assembly to create
                                      an insulating splice.
                         3M  Cold     Closed-ended tubular sleeves are   •   Exposed cables ends
                            ™
                                      factory-expanded and assembled
                         Shrink End   over removable core. Provides a   •   Cable reels housed in cable yards

                         Caps EC      reliable environmental seal when   •   Cables exposed to moisture    —  0.46–3.32


                         Series       positioned over the end of a cable    or weathering
                                      or other cylindrical object.
                                                                                                5300-5314:
                                                               •   Automotive manufacturing      #16 AWG–   5300-5314:
                         3M  Motor    Kits for splicing motor lead                               500 kcmil    0.06–0.81
                            ™
                         Lead Splicing   cables to incoming feeder cables.    •   Machine shops  up to 1000V
                         Kits 5300    Versatile sizing with pigtail or    •   Agriculture machinery  5316-5334:
                                      inline configurations. Easy and
                         Series       quick to install and remove.   •   Industrial machinery manufacturing  #8 AWG–   5316-5334:
                                                               •   480 volt electric motors
                                                                                                 500 kcmil
                                                                                                up to 5/8kV  0.20–0.81
   1   2   3   4