IGEM/G/4 Edition 2
             non-hazardous area
             Area in which an explosive gas/air mixtures is not expected to be present in quantities such as
             to require precautions for the construction, installation and use of apparatus.

             non-return valve (NRV)
             Valve which prevents the reversal of gas or air flow, constructed to meet agreed performance
             standards.

             non-routine operation procedure
             Formal written document used to control complex operations.

             normal (operating) conditions
             Conditions when no fault exists on any device or stream.

             normal operation
             Situation when equipment is operating within its design parameters.

             normal start-up rate
             Gas flow rate at which the main burner is normally ignited.

             Ofgem approved meter installer (OAMI)
             Ofgem registered gas meter fitters with a specific meter installation qualification.

             oil filming, relating to watersealed gas holders
             Oil pumped inside in  an attempt to prevent  gas contents from becoming wet because of
             evaporation of the tank water.

             one call system
             One telephone number for all Utilities.

             open at rest regulator
             Design of regulator in which the internal flow control element(s) is designed to be in the open
             position when all control and sensing connections are removed.

             open cut
             Method by which access is gained by excavation from ground level to the  required level
             underground for the installation, maintenance or inspection of a pipe, conduit or cable.

             open flue appliance
             Appliance designed to be connected to an open flue system.

             open flue system
             System that evacuates the products of combustion to the outside air and where combustion
             air is drawn directly from the room or space  containing  the  appliance, without the use of
             mechanical fans or ejectors.

             operating levels
             Set points of all control devices under operating conditions.

             operating margins, relating to transmission system design
             Volume of gas required to meet unforeseen circumstances such as:
               the demand forecast, prior to any day, is correct and the supplies set too low, for some
                time before the error is discovered. Subsequent within-day forecasts may also be incorrect
               failure of plant to operate
               supply failure.

             operating pressure (OP)
             Pressure at which a gas system operates under normal operating conditions.