Page 25 - Safety and health in construction
P. 25

Safety of workplaces

                     effective evacuation plan so that all persons are evacuated speedily without panic and
                     accounted for and all plant and processes shut down.


                         3.6.16. Notices should be posted at conspicuous places indicating:
                     (a)  the nearest fire alarm;
                     (b)  the telephone number and address of the nearest emergency services.




                     3.7.   Lighting

                         3.7.1.   Where natural lighting is not adequate to ensure safe working conditions,
                     adequate and suitable lighting, including portable lighting where appropriate, should be
                     provided at every workplace and any other place on the construction site where a worker
                     may have to pass.


                         3.7.2.   Artificial lighting should, as far as practicable, not  produce  glare  or
                     disturbing shadows.

                         3.7.3.   Where necessary to prevent danger, lamps should be protected by suitable
                     guards against accidental breakage.

                         3.7.4.   The cables of portable electrical lighting equipment should be of adequate
                     size and characteristics for the power requirements and of adequate mechanical strength
                     to withstand severe conditions in construction operations.











































                                                                                                         13