Permeable surfaces

      Permeable surfaces enable SuDS designers                     edge
      to direct rainfall straight into a SuDS                      ■  adjacent planting should include dense
      structure for cleaning and storage or                        ground cover to bind the soil in place
      infiltration into the ground.                                ■  slopes running toward permeable              Detailed Design

      There are a number of permeable surfaces                     surfaces should have a depression and
      available. All should have in common:                        ideally an underdrain before reaching
                                                                   the pervious surface.
      1.  a pervious surface to allow water through
          the pavement surface                               The design and construction of pervious
                                                             pavements are covered by guidance in the
      2.  an open-graded sub-base layer that
                                                             SuDS Manual (Section 20) and the Interpave
          provides structural strength to the
                                                             website www.paving.org.uk
          pavement with about 30% by volume
          available for water storage.                       There are no reported issues with surface
      3.  Silt washed off adjacent landscape areas           clogging under normal use. A dedicated
          can lead to localised surface clogging.            maintenance may be required after between
          This risk can be managed through design            10 and 20 years of use comprising a brush
          detailing as follows:                              and suction removal of grit joints and joint
             ■  slope adjacent landscape areas away          replacement.

             ■  use paved or turfed surfaces to
             adjacent areas
             ■  soil in adjacent planting beds should        Soft landscape areas are set below kerb level at      128

             be min. 50mm below the pavement                               this permeable paving installation.