Detailed Design  9.6.5  Flow controls for SuDS              Silt is trapped at source in SuDS components               9.6.6  The importance of protected openings                                                                  Detailed Design

                                                                                                                                                                                    SuDS components such as permeable
                                                                                                                             There are no minimum thresholds for
           Attenuation storage within sub-catchments
                                                                                                                                                                                    pavements, bioretention or filter drains are
                                                                                                                             attenuated flow rates in SuDS design.
                                                                  and settles out along the management train.
           and along the management train can require
                                                                                                                                                                                    pre-filtered, and assuming collection through
                                                                  Where slow movement of flow is maintained
                                                                                                                             Previously the drainage industry has applied
           several flow controls. Flow controls come in
                                                                                                                                                                                    perforated pipes or similar, the flow control
                                                                  throughout, floating debris that easily blocks
                                                                                                                             a minimum flow rate of 5 l/s but this does not
           many forms including orifice plates, slot or
                                                                                                                                                                                    opening requires little additional protection.
                                                                  outlets is not driven against openings; as is
                                                                                                                             take into account the need in SuDS for low
           V-notch weirs and vortex controls. Any type
                                                                                                                             flow rate controls and the design of
                                                                  the case with conventional drainage. Simple
           of flow controls can be prone to blockage
                                                                  design features such as sloping headwalls
           unless the opening is protected.
                                                                                                                                                                                    ponds and basins, require additional
                                                                  can direct floating debris past the outlet as
                                                                                                                                                                                    protection. One way to provide this
                                                                                                                             Small sites and sub-catchments of larger
           The rate of flow of water through SuDS
                                                                  the storage structure fills.                               protected openings.                                    Open SuDS components such as swales,
           components is slow as it is restricted to                                                                         sites may need to meet minimal outflow flow            protection is to use a stainless steel basket
           ‘greenfield rates’ of runoff through each flow                                                                    rates. Flows can be controlled down to 0.5             filled with 80-150mm stone with the
           control. There should always be an overflow                                                                       – 2 l/s using small openings (15-20mm                  connecting pipe opening set within the stone
           arrangement to deal with blockage or                                                                              diameter) with shallow depth of storage.               to prevent floating debris reaching the flow
           exceedance of the design storm.                                                                                                                                          control.
                                                                                                                             A stainless steel mesh basket filled with 80-
                                                                                                                             150mm aggregate forms an effective
                                                                                                                             protection for pipe openings. Note the pipe
                                                                                                                             opening has a mesh guard to stop stone
                                                                                                                             migrating through the pipe.

  97                                                                                                                                                                                                                                      98






                                                                  Orifice flow control chambers such as this one
                                                                  by Controflow are simple, reliable,
                                                                  cost-effective and easy to maintain.


                                                                  Flow controls in the landscape can make
                                                                  interesting features and help tell the story of
                                                                  how the system works.  Although more prone
                                                                  to blockage, features such as this slot weir at            Key points to be considered when designing                pass over the outlet as water rises in the
                                                                  Hollington School are very easy to unblock.
                                                                                                                             protected openings:                                       SuDS component.

                                                                                                                                ■  Protection to the opening should be of a            ■  Openings in the protective screen should
                                                                                                                                 reasonable surface area to allow for                  be smaller than the orifice opening size,
                                                                                                                                 accumulation of litter and vegetation                 thus any residual silt passing through
                                                                                                                                 across the surface of the protection.                 protective screen will pass through the
                                                                                                                                                                                       orifice opening.
                                                                                                                                ■  Outlets in open structures should be
                                                                                                                                 located on a slope to encourage debris to



           London Borough of Newham SuDS D & E Guide                                                     © 2018 McCloy Consulting & Robert Bray Associates  London Borough of Newham SuDS D & E Guide                                                     © 2018 McCloy Consulting & Robert Bray Associates