Page 45 - Newham SuDS DESIGN & EVALUATION GUIDE
P. 45

Concept Design  7.4.8   Method of discharge – how rainfall leaves the site  7.4.9  Preliminary flow and volume calculations  2  Concept Design

      It is convenient to consider flow and volume
 1.
 re-use on site
                                                             comparison of storage values between similar
 Rainfall should not discharge into the foul
                                                             sites.
 sewer.
      requirements at this stage in the design
 infiltration into the ground
 2.
      process to ensure that natural losses are
                                                             Expressing storage as ‘volume per m ’ allows
 The way that rainfall leaves a development
 3.
 a natural watercourse
      replicated and sufficient volumes of runoff
                                                             the designer to allocate storage throughout a
 should follow the preferred hierarchy:
      can be temporarily accommodated to allow
                                                             site in discrete sub-catchments, and provides
 4.
 surface water sewer
      for discharge from site via a flow control
                                                             a straightforward way for the evaluation team
      and/or infiltration.
 combined sewer.
 5.
                                                             acceptable.
      In some circumstances, for example where
      development is speculative, it may be                  to check that calculated storage volumes are
                                                             Ideally each sub-catchment will manage its
      acceptable for the Concept Stage to omit               own runoff up to the 1 in 100 year return
      flow and volume calculations, but a Modified           period rainfall event. Where this is not viable,
      Flow Route analysis will be required to show           part of the storage volume will be provided
      that runoff can be effectively conveyed to a           depending upon the opportunities for
 The final swale at Bewdley School is a colourful   discharge location.  storage within the subcatchment, with all
 outfall into the existing watercourse.
      Storage volumes are usually presented as a             residual flows cascaded into an adjacent
      single volume.                                         sub-catchment or ‘site control’.
      This form of expression encourages the ‘pipe           This approach maximises the opportunity for
      to pond’ practice and prevents simple                  storage throughout the development.
 39                                                                                   Flow control with            40

                                                                                      controlled discharge
                                                  C1
                                                 1 in 2 yr                            from one catchment to
                                                                                      the next


                                                                 C2                   Residual flows
                                                                 1 in 10 yr
                                         C3
                                        1 in 30 yr



                      C4
                        1 in 100 yr (+CCA)
                        + residual flows from
                            C1, C2 & C3 upto
                              1 in 100 yr (+CCA)

                                                             In this example the first three catchments
                                                             (C1, C2 & C3) only partially attenuate their
      Each catchment may only control and attenuate          own runoff, with residual flows passing into
      runoff up to lesser rainfall events (eg. 1 in 2        catchment C4 where these residual flows must
      years, 1 in 10 year, 1 in 30 years) with residual      be attenuated, along with C4’s own runoff, to
      flows passing into the next subcatchment.              the maixmum design storm (eg. 1 in 100 + CCA).


 London Borough of Newham SuDS D & E Guide                                                     © 2018 McCloy Consulting & Robert Bray Associates  London Borough of Newham SuDS D & E Guide                                                     © 2018 McCloy Consulting & Robert Bray Associates