9.6.1  Design flexibility

      A framework of three approaches which
      deliver variable outflow rates (Approach 1)

      are explored by this guide. These approaches
      are intended to inspire the designer to think                                                                Detailed Design
      about the possibilities that exist for
      integrating storage as part of the
      development rather than defaulting to an
      underground storage structure prior to
      discharge from the site. They can be
      summarised as follows:



      Distributed storage components


         ■  distributed storage volumes into discreet
          storage components such as raingardens,
          swales, basins and permeable pavement
          with the potential for different rainfall
          depths being stored at each location.





      Single, uniform storage components                                                                           94

         ■  store up to the 1 in 100 year rainfall in a
          single storage component, such as a
          permeable pavement or blue-green roof,
          with openings sized to achieve the
          variable outflow rates.






      Single, tiered storage components

         ■  store up to the 1 in 100 year rainfall in a
          single, tiered storage component, such as
          a smaller basin used on a regular basis
          within a more extensive basin for more
          extreme rainfall events and openings sized
          to achieve the variable outflow rates.






      Wyre Forest District Council SuDS D & E Guide                                                      © 2018 McCloy Consulting & Robert Bray Associates