For low to medium risk sites, the indices
      approach for discharge to surface waters is
      reasonably simplistic to apply.

      A level of understanding of the site’s soil and
      underlying geology is required to undertake                                                                  Detailed Design
      the infiltration risk screening assessment. The
      screening assessment will determine whether
      it will be permissible to infiltrate and the
      indices approach is applied to define the level

      of treatment required prior to the point of
      infiltration.

      Discussion will be required with EA where the
                                                              SPZ areas identified on the EA website:
      site overlies Source Protection Zones 1 or 2 or         http://apps.environment-agency.gov.uk/
      where contamination is identified on
                                                              wiyby/37833.aspx
      brownfield sites.












                                                                                                                   104






















                                                  Design Notes:
       On freely draining sites where insufficient treatment is provided at the first stage of treatment
           source control, initial SuDS components may require lining to prevent direct infiltration
                                  carrying pollutants into underlying geology.


         On low to medium risk sites permeable pavement will provide sufficient treatment prior to
                             infiltration into the ground via the pavement subbase.